Amber (solid)
Green 12.5
Battery/Inverter Mode. Inverter is running.
Display shows battery voltage in DC volts
Amber ‘0.80’
Battery/Inverter Mode. Inverter is running,
Display shows output power in kW (800W
as shown)
Amber (ashing)
Battery (Inverter) Mode and AC Input is detected and unit will switch to By-
Pass mode within 20 seconds
Red (solid) OFF E01-E12
Unit has shutdown. Display shows error code
(See error code reference chart below)
Note: ‘Status LED’ is used to indicate the status of the unit.
Green: By-Pass Mode
Amber: Battery (Inverter) Mode
Note: ‘Display LED’ is used to indicate the digital display function.
• Green: Display is showing Battery voltage in volts.
• Amber: Display is showing Output power in KW.
Understanding the ‘Power’ and ‘Select push button function during
normal operation
A beep sound will occur every time the ‘Power’ or ‘Select’ button is pressed.
‘Power’ button function:
Turns the inverter On/O during Battery Mode. Press and hold it for 1 second to turn the unit either
ON or OFF.
Note: The ‘Power’ button can be used to turn the AC Output OFF during AC By-Pass (when set in ‘PS4’
mode) without the need to disconnect the AC-Input as per “PS1” setting. See more on “Understanding
the unit setting”.
‘Select’ button function:
• Check the unit setting: Press once to check or verify unit’s present set functions
AC Load on the ePOWER Inverter
Although the ePOWER Inverter can provide high surge power up to two times the rated output power,
some appliances may still trigger on the inverter protection system. A higher power inverter is required
for those appliances.
Estimate Run Time On Load
Following run times are estimates for reference, based on using dierent battery bank sizes. Actual
run times may vary.
Important: Power Drain from DC Battery Bank.