Manual

Enerdrive ePOWER Inverter Owners Manual (Rev. 1.0)Page 16
Please note that there is a power drain of approx 700mA from the battery bank when the Inverter is
running in AC By-Pass mode. In order to avoid draining down the battery bank, a battery charger with
sucient power is required to maintain the battery bank voltage.
Estimate run time on dierent 12V Battery Bank Size
AC Load 60AH 120AH 180AH 240AH 300AH
50 W 11 hrs. 22 hrs. 33 hrs. 44 hrs. 55 hrs.
100 W 5 hrs. 11. 5 hrs. 17 hrs. 23 hrs. 29 hrs.
200 W 2.5 hrs. 5 hrs. 8 hrs. 11 hr s . 13.5 hrs.
500 W 49 mins 2 hrs. 3 hrs. 4 hrs. 5 hrs.
1000 W 15 mins 49 mins 1.5 hrs. 2 hrs. 2.5 hrs.
1500 W 8 mins 27 mins 49 mins 1 hr 1.5 hrs
2000 W N.R. 15 mins 34 mins 49 mins 1 hrs
2600 W N.R. 11 mins 25 mins 37 mins 49 mins
Note: N.R. - Not Recommended