User Manual

Understanding the Display & Function Keys during normal operation
Display
Digital Display LCD with back lighting
Digital Display Info : CH1
CH2 & CH3
Fault/Warning
Charging Status, Voltage, Current
Voltage
Error code E01-08, Warning A01-02
‘CH3’ Icon Flashing
CH3 > 12.0V on a 12V Input system
CH3 > 24.0V on a 24V Input system
and not charging from (alternator)
‘CH3’ Icon Solid Charging from CH3 input (Start Battery / Alternator)
‘CH2’ Icon Flashing CH2 > 14.5V and not charging from solar array
‘CH2’ Icon Solid Charging from CH2 input (solar)
During normal operation, the display will cycle through and show CH1 battery voltage,
charging current and charging stage (‘bul’ – Bulk stage, ‘Abs’ – Absorption stage, ‘Ful – Float
stage) alternatively. When the ‘MENU’ key is pressed, it will display the other channel’s
battery voltage only
CH3 icon will ash when the input voltage is above (> 12 on a 12V system or > 24V on a
24V system and it is not the source charging the battery. It will change to solid when it
becomes the source charging the battery.
CH2 icon will ash when the input voltage is above the Flashing Voltage (> 14.5V) and is
not the source charging the battery. It will change to solid when it becomes the source
charging the battery.
During normal operation, Every time the menu button is pressed once, the display will
scroll through and show CH1, CH2 & CH3: Voltage’ for 3 seconds and it will return to the
normal display automatically. If CH2 or CH3 is not connected, it will show 0V.
The display will remain ON when either one or both CH2 & CH3 inputs are available. The
display will turn OFF if CH2 or CH3 is not available.
During equalisation operation (for ooded batteries only), the numerical section on the
display will show a ashing ‘eq’ indicating the equalisation process is in progress and it
will not show the battery voltage or the charging current.
Understanding The Function Key ‘MENU’, ‘SET’ And ‘SEL’ During
Charger Setting
CH1 - display is showing the charging battery
info (charging status, voltage and current).
CH2 or CH3 - When displayed symbol is solid
this means the power is coming from the related
channel and the other channel will be ashing if
it is connected but not charging.
“V“ - Display is showing the voltage
“A“ - display is showing the current
“Auto - units Silent mode is switched on
“Priority - the units “ignition Sense” terminal
is connected or the unit is set to Manual Override
mode
“Mode“ - charging mode setting*
“Temp“ - Temperature setting*
*Will only display when selected setting is active
Digital Display:
During the charging process, the display shows ‘CH1’ charging status, voltage and current
repeatedly, and ‘CH2’ or ‘CH3’ symbol is solid to indicate the active input source. If the other
input channel is available and the voltage is above the ‘CH2 and CH3 Flashing Voltage’ the
icon will be ashing. When the menu button is pressed once, the display will change to
show CH1 Voltage for 3 seconds, CH2 voltage for 3 seconds and CH3 voltage for 3 seconds.
The display will then revert back to normal operation and will show the CH1 info.
When the Battery (CH1) is fully charged, it will show ‘CH1’ and ‘FLO, voltage and current
repeatedly on the display.
The selected “battery type” icon is always ON at all times during the whole charging process.
The ‘Priority’ Icon turns ON when the “ignition sense” terminal is connected or the unit is
set to ‘Manual Override’ mode.
Priority
Enerdrive ePOWER DC2DC 24V Battery Charger Owners Manual (Rev. 1.5) www.enerdrive.com.auPage 24 Page 25