User Manual

Mounting The Charger
Choose an appropriate mounting location.
For installing in an indoor location, the unit should be mounted vertically (with the
battery terminals facing downwards). This provides the best thermal performance and
drip protection. The unit should NOT be mounted upside down.
For installing in a boat or marine environment, the unit should only be mounted vertically
(Battery Terminals facing downwards only) to provide adequate drip protection.
Use the base of the charger as a mounting template to mark the positions of the xing
screws.
Drill the 4 xing holes and place the Charger in position and fasten the unit to the mounting
surface.
119mm 55mm
160mm
6. CONNECTING THE CHARGER
Chassis Grounding Connection
BEST PRACTICE
This Charger SHOULD BE CORRECTLY GROUNDED.
The unit chassis has a stud point on it for grounding. Connect the unit’s chassis ground to
the common ground point through the ground stud located near one of the unit mounting
slots. (Battery DC negative is the best ground reference point in your installation) .
DC Output Wiring
WARNING: Correct DC Wiring Is Required
The DC wiring used must be of appropriate size.
An individual fuse or breaker is required to be installed within 20cm of the both the start
battery and house battery bank.
A DC isolator or fuse is also recommended for the solar input.
All devices must be rated for DC voltage and current.
The solar input fuse or breaker must be able to withstand the short circuit current rating
stated on the solar panel array.
All wiring must conform or exceed the recommendations stated in this manual (page 17).
This is a Dual Input device. Dierent cable sizes are required for the alternator input,
solar array input and the DC2DC 24V charger to battery connection.
Enerdrive ePOWER DC2DC 24V Battery Charger Owners Manual (Rev. 1.5) www.enerdrive.com.auPage 14 Page 15