Operation & Owner’s Manual 24V, 36V & 48V Models Rev: 1.
PLEASE KEEP THIS MANUAL FOR FUTURE REFERENCE For safe and optimum performance, the Enerdrive ePOWER Industrial Battery Charger must be used properly. Carefully read and follow all instructions and guidelines in this manual and give special attention to the CAUTION and WARNING statements.
NOTICE OF COPYRIGHT Enerdrive ePOWER Industrial Battery Charger owner’s manual © 2021 Dometic Power & Control (Enerdrive) Pty Ltd. All rights reserved. No part of this document may be reproduced in any form or disclosed to third parties without the express written permission of Dometic Power & Control (Enerdrive) Pty Ltd, P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178.
Table of Contents 1. INTRODUCTION: IMPORTANT SAFETY INFORMATION: 5 5 2. PRODUCT DESCRIPTION: 7 3. INSTALLATION: 7 4. OPERATION ILLUSTRATION: LED INDICATORS DURING START UP: 7 7 BATTERY CAPACITY INDICATORS: 9 5. 6. CABLE CONNECTIONS: MAINTENANCE INSTRUCTIONS: 10 13 7. FAULT INDICATOR: 14 8. WATERPROOFING INSTALLATION: 16 9. SPECIFICATIONS: 17 10. CHARGE PROFILE: CHARGE PROFILE INSTRUCTIONS: 18 18 CHARGE PROFILE TABLE: 19 11.
1. INTRODUCTION Thank you for purchasing the Enerdrive ePOWER Industrial Battery Charger. With our state Please read and follow these instructions and precautions carefully. IMPORTANT SAFETY INFORMATION: This section contains important safety information for the Enerdrive ePOWER Industrial Battery Charger.
WARNING FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH OR SERIOUS INJURY • When working with electrical equipment or lead acid batteries, have someone nearby in case of an emergency. • servicing the battery connected to the charger. • Wear eye protection and gloves. • Avoid touching your eyes while using this unit. • Keep fresh water and soap on hand in the event battery acid comes in contact with eyes.
WARNING • Enerdrive recommends that all wiring be done by a skilled technician to ensure adherence to the best practice standards for on-board DC electrical installations. Failure to follow these instructions can damage the unit and could also result in personal injury or loss of life. CAUTION • Before Beginning Your Unit Installation, Please Consider The Following: • The unit should be used or stored in an indoor area away from direct sunlight, heat, moisture or conductive contaminants.
LED Indicators and Digital Display: Charger will enter charging model when connecting to battery & AC input cable. Digital display on the front panel will show in turn: AC XXX (Current AC input voltage), CPU X.XX (corresponding software version number), b**(Current charging profile code). To change the charging profile, press & hold the Select button for 5 seconds, then press the Select button to choose the desired profile.
Battery Capacity Indicators: LED4 Capacity LED3 LED2 LED2 (100%) LED1 LED3 (75%) (Blinking) <50% (Blinking) >50% >75% LED4 (50%) (Blinking) 100% LED 1 LED 2 (100% Indicator) LED 3 (75% Indicator) LED 4 (50% Indicator) Algorithm 30+ Algorithm 20+ Algorithm 10+ Algorithm 1 - 9 For example; www.enerdrive.com.
5. Connecting the Cables: 1 2 3 4 5 6 7 1. Connect to the positive terminal of the battery 2. 3. Connect to the negative terminal of the battery / BTSConnect to the BTS+ 4,5,6: Interlock Cable (4,6: NO the interlock cables will form an open circuit with no voltage. 5,6: NC The interlock cable will form a short circuit with no voltage). 7. Connect CANBUS or LED light wire (optional function).
Always connect the positive cable to the battery first, then the negative cable to the negative (chassis for B negative grounded vehicles) prior to connecting to supply mains. After charging, and when removing charger, always disconnect the battery charger from the supply mains, then disconnect the negative/chassis connection and then the positive connection. Supply mains wiring in fixed installs such as caravans or similar vehicles must be in accordance with the national wiring rules.
Always connect the positive cable to the battery first, then the negative cable to the negative (chassis for negative grounded vehicles) prior to connecting to supply mains. After charging, and when removing charger, always disconnect the battery charger from the supply mains, then disconnect the negative/chassis connection and then the positive connection.
Always connect the positive cable to the battery first, then the negative cable to the negative (chassis for negative grounded vehicles) prior to connecting to supply mains. After charging, and when removing charger, always disconnect the battery charger from the supply mains, then disconnect the negative/chassis connection and then the positive connection. Supply mains wiring in fixed installs such as caravans or similar vehicles must be in accordance with the national wiring rules.
7. FAULT INDICATION WITH LED DISPLAY When a fault occurs, LED2(100%)/LED3(75%)/LED4(50%)will blink at the same time. Blinking Frequency (every 4 sec) Solution The battery is not connected or the battery voltage is too low 1) Check battery connection is correct. 2) Check charger connection is correct. 3) Check each battery is good. Abnormal AC Power Input (Voltage) 1) Check AC input cord is connected between charger and AC outlet. 2) Make sure AC plug is tightly inserted into AC outlet. 3.
WITH DIGITAL DISPLAY Blinking Frequency Fault Cause E01 bAt The battery is not connected or the battery is in reverse or the battery is damaged 1) Check battery connection is correct. 2) Check charger connection is correct. 3) Check each battery is good. E02 AC Abnormal AC Power Input (Voltage) 1) Check AC input cord is connected between charger and AC outlet. 2) Make sure AC plug is tightly inserted into AC outlet.
8. WATERPROOFING INSTALLATION Waterproof ring installation of the AC input cable. 1. Slip waterproof ring or grommet over the AC input cable 2. correctly 3. *NOTE: Take care to not overtighten the waterproof clamp. Page 16 Enerdrive ePOWER Industrial Battery Charger Owner’s Manual (Rev. 1.
9.
10. CHARGE PROFILE NOTE: You will require a formatted (FAT32) USB memory stick with a capacity of 1024KB or larger. 1. Download and save the Battery Algorithm Listing from the download link www.enerdrive. com.au/Algorithm/ePOWER-algorithm.xlsx 2. Listing” tab in this spreadsheet. 3. 4. 5. Make sure the charger is NOT connected to the battery or AC power. 6. Unscrew the round cap covering the USB port on the front of the charger and insert the USB memory stick. 7.
Algorithm No.
11. WARRANTY 5 Year Warranty In the unlikely event that a technical issue arises with an Enerdrive product, customers are encouraged to initially contact the Enerdrive Support Team on 1300 851 535 or support@enerdrive.com.au for immediate and efficient expertise and first class product support. Important Note: Consumer Protections If you have purchased your product in Australia, you should be aware that: This warranty is provided in addition to other rights and remedies held by a consumer at law.
DOMETIC POWER & CONTROL (ENERDRIVE) PTY LTD P.O. Box 9159, Wynnum Plaza, Queensland, Australia 4178 Ph: 1300 851 535 / Fax: 07 3390 6911 Email: support@enerdrive.com.au Web: www.enerdrive.com.