User Manual

Lithium Battery charging algorithm
14.4V
14.2V
14.0V
13.8V
13.6V
13.4V
13.2V
13.0V
12.8V
Battery Current
Bulk Power Supply Mode
Time out 8 hrs max Time out 7 days
Diagram does not illustrate our current set points.
Maint. Power Supply Mode Return to Bulk
Battery Voltage
13.3VDC triggers
Bulk Restart
Note: Actual voltages depend on chosen algorithm.
Battery Charger Voltage
Battery Type Absorption Float (See Note 3) Equalisation
GEL 14.4 V 13.7 V N.A.
AGM 14.6 V 13.6 V N.A.
Flooded 14.4 V 13.3 V 15.5 V (See Note1)
Lithium
13.9 V-14.6V (0.1V Step)
(see Note2)
13.5V-14.2V
(0.1V Step)
N.A
Program (Custom
Settings)
13.8V-14.8 (0.1V Step) 13.0V-13.8 (0.1V Step) N.A
* For Concorde™ branded batteries (lifeline, sun xtender) use ooded setting and consult battery
supplier for equalisation recommendations.
Note 1: Equalisation setting can only be used on ooded battery type selection only. See
more details on Procedure to Equalise the Flooded Battery.
Note 2: Charger will terminate charging when charging current drops to below the set
charger termination value.
Note 3: Charger is acting as a power supply with selected constant output voltage and
preset maximum output current.
www.enerdrive.com.au Page 11