absorption-to-oat mode current settings.
For Charging Lithium Batteries
This can only be set at Bank 1, it has its own charging voltage and current
setting. It also requires the user to set the charger termination current.
The charging process will terminate when the charging current drops to
the set termination current. Bulk re-start occures when battery voltage
drops below 13.3V DC.
For Using Charger As Power Supply (Program Setting)
NOTE
With this setting, only Bank 1 can be used and the other banks are disabled.
The charger can be used as a constant voltage power supply that will
deliver the preset output voltage (13.3, 13.5, 13.7 V) with the maximum
current setting. With this setting, only Bank 1 can be used and the other
banks are disabled.
Understanding The Display And Function Keys During Normal
Operation
During normal operation, the display shows the related channel’s battery
voltage, charging current and charging stage (‘bul’ – Bulk stage, Abs’
Absorption stage, ‘Flo – Float stage) alternatively. When the ‘MENU’ key
is pressed, it displays the other channel’s battery voltage only.
When all channels reach oat stage, the display will show ‘Ful’ indicating
all the batteries connected are fully charged and presently in oat mode..
During equalisation operation on ooded battery only, the numerical
section on the display will show a ashing eq’ indicating the equalisation
process is in progress and it will not show the battery voltage or the
charging current.
Enerdrive ePOWER Battery Charger Owner’s Manual (Rev. 5.2) Dec 2015Page 22