Manual

EPL-100BT-12V-G2
3.90V ± 0.03V
5s Auto Release
Disconnect Load
Protection to 65°C ± 5°C
Release at 50°C ± 5°C
Release at 55°C ± 5°C
Release at 45°C ± 5°C
Auto release after 5s
Length 318mm Length 318mm Length 505mm
Width 165mm Width 165mm
Width 172.5mm
Height 215mm Height 215mm Height 265mm
Approx 12.6 kg Approx 15.0 kg Approx 25.0 kg
≤30 days -20°C to 35°C,
45 to 75% RH
≤ 30 days -20°C to 35°C,
45 to 75% RH
≤ 30 days -20°C to 35°C,
45 to 75% RH
≥ 30 days -10°C to 30°C,
45 to 75% RH
≥ 30 days -10°C to 30°C,
45 to 75% RH
≤30 days -20°C to 35°C,
45 to 75% RH
≤3% Per Month ≤3% Per Month ≤3% Per Month
Battery Discharge Over Temperature
Battery Charge Over Temperature
Short Circuit Protection
Mechanical Characteristics
Dimensions
Weight
Storage Information
Temperature & Humidity Range
Self-Discharge Rate
Over Temperature Protection
12.8V
≤11.20V≤11.20V≤11.20V
≤60A
100Ah
11.20 - 14.60V
Discharge below release voltage
Over-Charge Release Per Cell
Over-Charge Release Method
Circuit Protection
Section 9 - Battery Specifications
www.enerdrive.com.au Page 13
Enerdrive B-TEC Lithium Battery Technical Data
Normal Specification EPL-100BT-12V-G2 EPL-125BT-12V-G2 EPL-200BT-12V-G2
Standard Charge Specification (Lithium profile charger required)
Standard Discharge Specification
Nominal Voltage
12.8V12.8V
≤2000 Cycles
≤33A
≤40A
0 - 45°C
60A @ 25°C for 30 mins
-20 - 60°C
11.20 - 14.60V 11.20 - 14.60V
450A for 1.0s
100A @ 25°C ± 5°C for 30 mins 100A @ 25°C ± 5°C for 30 mins 200A @ 25°C ± 5°C for 30 mins
3.60V ± 0.05V
80A @ 25°C for 30 mins 150A @ 25°C for 30 mins
14.20 - 14.60V14.20 - 14.60V14.20 - 14.60V
13.50 - 13.80V 13.50 - 13.80V 13.50 - 13.80V
125Ah 200Ah
Nominal Capacity
Battery Charge Temperature
Normal Charge Voltage CV/CC*
Standby (Float) Voltage
Maximum Charge Current
Battery Discharge Temperature
Battery Output Voltage Range
Maximum Discharge Current
Pulse Discharge Current
Discharge Cut-off Voltage
Over-Charge Protection
Over-Charge Protection Per Cell
2.80V ± 0.05V
Yes Yes Yes
3.20V ± 0.05V
110A for 30s - 450A for 1s 110A for 30s - 450A for 1s 220A for 30s – 450A for 1s
Apply Charge/Voltage ≥12.8V
Apply Charge/Voltage ≥12.8V Apply Charge/Voltage ≥12.8V
Over-Discharge Protection Per Cell
Over-Discharge Release Per Cell
Over-Discharge Release Method
Battery Manual Reset Button
Discharge Over Current
Protection Reset Time
Over Current Release Method
Over Current Protection
Over-Discharge Protection
The battery is supplied with a LiFeP04 Battery Management System (BMS) that can monitor and optimise each single prismatic cell during charge and discharge, to
protect the battery pack from overcharge, over discharge and short circuit. Overall, the BMS helps to ensure safe and accurate operation of the battery.
Recommended Charge Current for Maximum Life
Cycle Life (DOD-80% under controlled conditions)