Manual
www.enerdrive.com.au Page 35
10. TECHNICAL SPECIFICATIONS
Parameter ePRO Plus
Supply voltage range 7..70Vdc
Supply current (@ 12V/ 24V/48V) 10mA / 6mA / 5mA
Input voltage range main battery (+B1) 7..70Vdc
Input voltage range second and third battery (+B2, +B3) 1..70Vdc
Input current range -600..+600A
Battery capacity range 10..10000Ah
Operating temperature range -20..+50°C
Storage temperature range -30..+70°C
Readout resolution Voltage (0..70V)
Current (0..10A)
Current (10..100A)
Current (100..600A)
State of Charge (0..100%)
Time remaining (0..24hrs)
Time remaining (24..240hrs)
Amphours (0..10000Ah)
Power (0..42kW)
Temperature (-20°C..+50°C)
± 0.01V
± 0.01A
± 0.1A
± 1A
± 1%
± 1min
± 1hr
± 0.01Ah..10Ah (variable)
± 0.01W..1kW (variable)
± 0.5°C
Voltage measurement accuracy ± 0.3%
Current measurement accuracy ± 0.4%
Shunt dimensions: Footprint
Base height
Total height
Weight
100 x 100mm
24.0mm
64.5mm
290grams
Display dimensions: Front panel
Body diameter
Total depth
Weight
Ø 64.0mm
Ø 51.5mm
36.0mm
70grams
Protection class IP20 (CDU front panel only
IP65)