Faults
Cable connection is correct,
LCD Screen not displayed
Icon blinking
Icon blinking
Icon blinking
Icon blinking
Battery over voltage
Battery over discharged
Battery over heating
Over load or short circuit
Reduce the output loads and/or check
load terminal connections
When the battery voltage is restored to
or above LVR (low voltage reconnect
voltage) point, the load will recover
PV array disconnection
1). Battery voltage is lower than 9V
1). Please check the voltage of battery
At least 9V is required to activate the
controller
2). Check the PV input voltage which
should be higher than the battery
voltage
Check if the battery voltage is
higher than the OVD (over voltage
disconnect voltage) point, and
disconnect the PV
Possible Reasons Troubleshooting