Wiring Connections
1. Connect components to the charge controller in the sequence as shown above (1,2,3) and pay
particular attention to the “+” and “-”. Please don’t insert the fuse or turn on the breaker during the
installation. When disconnecting the system, the order will be reversed, (3,2,1).
2. The battery fuse should be installed as close to the battery as possible. The suggested distance is
within 150mm.
3. Always connect the battery rst, in order to allow the controller to recognize the system voltage.
4. Power up the controller and conrm that the LCD screen turns on. If the screen does not power
up, refer to page 14 TROUBLESHOOTING.
5. The ePOWER Solar Charge Controller is a common Positive Controller.
NOTE: If using an inverter, or have a load larger than the load output of the solar controller, connect the
inverter and/or large load/s directly to the battery.
USB
Charging
Cable
Fuse
Fuse
Battery Bank
12V/24V
Breaker
Solar
Solar Controller
Phone or Tablet
1
3
Inverter
Load
2