EG-PMS2-WLAN PROGRAMMABLE SURGE PROTECTOR WITH WLAN INTERFACE USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ КЕРІВНИЦТВО КОРИСТУВАЧА
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Programmable surge protector with WLAN interface Programmier- und steuerbare Steckdosenleiste mit WLAN-Anschluss Programmeerbare WLAN stekkerdoos met overspanningsbeveiliging Boîtier commandé à distance et programmable avec prise WLAN Программируемый фильтр питания с WiFi интерфейсом Програмований мережевий фільтр з WLAN ынтерфейсом.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 1. Introduction Congratulations with your purchase of this Programmable WLAN Surge protector. Your EG-PMS2-WLAN is an advanced surge protector with power management features. Four sockets are individually manageable via your local WiFi network or the internet. The sockets can be switched on/off by a timer schedule, manually by user or by different programmable events.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR It is also possible to assign an external IP-address to EG-PMS2-WLAN, to enable worldwide remote access via the Internet No external IP-address at home? No problem. Create your own user account on EnerGenie.com to manage your EG-PMS2-WLAN via Internet with any PC or smartphone. Switching on your coffee maker before setting off for home becomes a reality.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Hardware schedule possibilities: Maximum number of independent hardware schedule events – 45 per socket Time setting accuracy in seconds Combine periodical and once events Timer accuracy: not more than 2 seconds error per day in case that power is always present.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 1.3. Hardware requirements Local area network with WLAN router Any Internet-enabled computer connected to the local area network Computer running Windows® 2000/XP/7/8 is required for using the Power Manager software (use of this software is not compulsory) 1.4.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 2.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 2.1.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 3 Power On / Reset (after power consumption exceeds 2500 Watts) Power cord Off Main rocker switch (Z) with power indicator and self recovering fuse 9 All brands and logos are registered trademarks of their respective owners
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 2.2.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 3.1. Getting started Screw the supplied antenna into the antenna socket of EG-PMS2WLAN. Connect EG-PMS2-WLAN to the wall socket. EG-PMS2-WLAN can now be switched on and off by means of the Main rocker switch (Z). Two (the first and the last) sockets of EG-PMS2-WLAN are marked with the symbol .
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR As soon as you turn the Main rocker switch (Z) on then the web server, Power manager software or the hardware schedule will be able to turn the manageable sockets on and off. Master switch button (B) (see Figure #2 above) can also switch all the manageable sockets on and off regardless of their current status or schedule that is being executed. To switch them on you should keep the button pressed for 1-2 seconds.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR For the configuration you will have to use any PC which is located within the reach of your wireless network. Insert the Power Manager CD into the PC CD-ROM drive. If for any reason the automatic setup does not work, then open CDROM drive in the My Computer window and launch SETUP.EXE from the CD If your laptop does not have CD-ROM player, just download the latest software from www.energenie.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR corresponding fields in the WLAN config window, then press the “Configure” button. Figure # 4 The configuration might take some time - wait until it is completed. If you see a string “Connected to SSID:” (as shown on Figure #5 below) it means that the connection to the wireless router has been successful.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 5 If your router has a DHCP server, it will assign IP address to EGPMS2-WLAN automatically. Alternatively, you could input them manually using the checkbox “Manual IP settings” and then entering IP settings into the corresponding fields. Don’t forget to press the “Configure” button to complete the manual IP configuration.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Now the wireless configuration has been completed. You can now disconnect USB cable from the device. Click “Go to device” button to access the device via web-interface (see section 4 for further details). Important note: SSID broadcast option must be enabled in WLAN router for successful connection of EG-PMS2-WLAN. If you ever lost the IP address of EG-PMS2-WLAN on your network, you could use LAN Find utility (See Figure #6 below) to find it.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 6 17 All brands and logos are registered trademarks of their respective owners
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 4. The web server Your EG-PMS2-WLAN is equipped with a web-server which allows managing the device using any web browser such as Internet Explorer, Firefox, Chrome, etc. 4.1. Web-server login page To access the web-server of EG-PMS2-WLAN, just open Internet Explorer (or other browser) and input the IP address of EG-PMS2-WLAN (for example http://192.168.1.241).
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR After a successful login you will face the EnerGenie page (see section 4.2 below). NOTE: There is a possibility that you might then need to open the LAN settings page (see section 4.5 below) to complete the IP configuration. 4.2. EnerGenie page With the help of EnerGenie page (see Figure #8 below) you will be able to see the status of all your four manageable sockets, and to switch the sockets on and off manually.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR assigned to your account. To register the device, simply push the button Register on this page (see Figure #6 below). You will then be redirected to Login page of EnerGenie.com. If you already own an account at EnerGenie.com then just enter your login and password on this page and you are done. Otherwise, use the Registration button on the Login page to create a new account.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 8 21 All brands and logos are registered trademarks of their respective owners
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR After a successful registration and activation the button Register will be renamed to Login (and will then open the Login page of EnerGenie.com) and the button Activate will turn into Deactivate. If by any reason you would eventually decide to stop managing your EGPMS2-WLAN from Internet use then Deactivate button to stop communication of the device with EnerGenie.com server.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 9 The socket shown on the Figure #9 is currently off, it will be turned on again automatically on the 9th of July at 14:40:30 and on the same day at 14:50:45 it will be switched off.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR and at 14:30:15 it will be switched off. Last two events will be executed each day staring from the 10th of July. Below the page you can see the current time of the web-server and eventual information about the last successful timer synchronization. Automatic timer synchronization is used if Use NTP for timer correction option is enabled (see section 4.6 below). NOTE: If a certain socket has a switching fault, e.g.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 10 Choose the date and time of the scheduled event.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR loop period. To commit to your changes press the Apply button. To delete the entered schedule press the Clear schedule button. NOTE: The hardware schedule keeps running even when the device is powered off. However it is recommended not to power off the device for longer than 1 week, because the built-in battery might get discharged then. In this case the internal clock of the device would be reset and as result some schedule events would not be executed.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 11 27 All brands and logos are registered trademarks of their respective owners
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 4.5.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR On the LAN settings page (see Figure #12 above) you can set up DHCP, IP address, Subnet mask, Gateway, DNS server and IP filter (up to 3 IP addresses can then be enabled for remote access). The new settings will be applied immediately after you press the Apply button. IP address, Subnet mask, Gateway, DNS server will be used only if the DHCP option is disabled.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Wireless Network Name (SSID) is the name of network, it can be set manually or via the WLAN Configuration utility. Authentication should correspond to the settings of your wireless router in AP mode. It can be set to WEP64, WEP128, WPA-TKIP, WPA2AES. With WEP64 or WEP128 authentication modes, you might additionally have to choose the Key index (from 1 to 4, usually 1), which corresponds to that key (pass phrase).
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 4.6. Device settings page On the device settings page you can setup name, password and internal time of EG-PMS2-WLAN (see Figure #13 below).
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR To be able to setup the schedule of EG-PMS2-WLAN you have to first setup its internal clock correctly. Enter the current local time and date. Alternatively if the option Use NTP for timer correction is enabled (by default) then the time will be taken from NTP server. The device will try to connect with the server every 18 hours. The first synchronization would take place in 15 seconds after you press the Apply button.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Don’t forget to push the Apply button to save your settings. 4.7. Web-server logout Having finished working with EG-PMS2-WLAN, choose Log Out in the main menu. If you don’t do this, you will be logged automatically after 10 minutes of inactivity. While you are logged to the web server, it can’t be accessed from any other computer.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 5.1. Logging in To login into your EnerGenie account just open the webpage www.energenie.com/user in your Internet browser and enter your login and password in the login window (see Figure #14 below). Figure # 14 Check Remember me checkbox for automatic login in the future (the website will then save a cookie on your computer). If you lost your password, click Forgot password button.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 5.2. Device management page After a successful login you will see the list of your registered devices and their corresponding sockets (see Figure # 15 below).
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR This page will automatically update itself and will keep showing you the time when your device was last seen online (the latest time when the device communicated with the server) and the status of each socket. Click your user name to change your account settings. Click the device to change its name and/or transfer it to another account. Click the sockets to change their names Click the On/Off buttons to switch the sockets on or off.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 6. Power Manager software The Power Manager software is designed to support not only EGPMS2-WLAN but also other power management family products (please visit www.energenie.com) . 6.1. Finding EG-PMS2-WLAN To be able to manage preconfigured EG-PMS2-WLANs, please, do the following: Install Power Manager software on a PC connected to your local network.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 16 The LAN devices window (see Figure #17 below) will appear, click Add button there to add a new EG-PMS2-WLAN device.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 17 In the Add LAN device window (see figure #18 below) please, enter correct IP address, port number (5000 by default) and password (1 by default) as configured on the Device settings page (see section 4.6 above) of the web server. To disconnect from the device uncheck the option Enable, set this option again to regain the access. Click OK button to return to the LAN devices window.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 18 Specified device should then appear with a green square next to it and Connected status in the LAN devices window (see Figure #19 below). NOTE: Antivirus or firewall software may block connection to EGPMS2-WLAN.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 19 To edit the WLAN device, select it and click the Edit button, or just double click on the LAN device To remove the WLAN device, select it and click the Remove button. You can select multiple WLAN devices using Ctrl and Shift keys. You can also remove all WLAN devices by clicking the Clear button HINT: Use the popup menu which can be activated by the right mouse button click over the table.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR If the status of EG-PMS2-WLAN shows the device not to be Connected - it could be due to the following reasons: Incorrect IP/Port/Password specified in the Add LAN device window PC is not connected to the local network You are trying to access EG-PMS2-WLAN from the PC which is not allowed to do so. Change PC IP address or change IP filter list in EGPMS2-WLAN hardware settings (see section 4.5 above) EG-PMS2-WLAN is not connected to local network.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 20 EG-PMS2-WLAN is connected to local network (ping test is ok) but not responding. Reset EG-PMS2-WLAN by pressing the Reset button (A) on the side control panel (see Figure #2 above) or switch it off and then on again (see Figure #1 above) NOTE: The Reset button A (see Figure #2 above) can sometimes help if EG-PMS2-WLAN can’t be accessed or works abnormally. The device will then be restarted.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 6.2. Managing EG-PMS2-WLAN After successful connection, close LAN devices window. You can now start managing EG-PMS2-WLAN via the Power Manager interface. Double click on the socket icon in the system tray or select Open from the popup menu (see Figure #16 above). You will get the window of the main control panel shown on the Figure #21 below.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Sockets should switch on and off (green color means the socket is switched on; red color means the socket is switched off) when you double click on them. Click the Settings button for each socket to access the Settings dialog box (see Figure #22 below).
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR You can choose a different device and another socket from the Device and Socket drop down list-boxes. It is possible to give a name to the device and socket (for example Printer or Scanner) using the Rename button Check the System tray checkbox if you want to put the icon of the socket into the system tray. You can choose the icon from drop down list box.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 7. Power Manager core features 7.1. Setting up the hardware schedule Using the Hardware schedule button available from the Settings window (see section 6.2 above) you can create the hardware timer schedule (see Figure #23 below). To add a new record, click the Add button.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR The window Add entry will appear (see Figure #24 below). In the dialog box, specify the required time and the action Figure # 24 To edit the record, select it and click the Edit button or just double click on the entry (see Figure #23 above). The window Edit entry will appear To remove the record, select it and click the Remove button (see Figure #23 above). You can select multiple entries using Ctrl and Shift keys.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR specify the loop time period in the Edit loop period window (see Figure #26 below) Figure # 26 After the schedule record has been created, click the Apply button (see Figure #23 above) to save the hardware timer schedule changes. In case of incorrect entries, these will be highlighted and an error message will appear.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR NOTE: The hardware schedule keeps running even when the device is powered off. However it is recommended not to power off the device for longer than 1 week, because the built-in battery might get discharged then. In this case the internal clock of the device would be reset and as result some schedule events would not be executed. Besides all the sockets would lose their previous status (they will be switched on).
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 27 To add a new task, click the Add button.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 28 In the Add task window, check Switch ON time and/or Switch OFF time checkboxes and specify the time to switch the socked on and/or off. If you want the same event to be performed periodically, check Perform task every checkbox and specify the time interval. You can also add remarks about the task in the Comment field. To disable the task, uncheck the Enabled checkbox and to enable the task again, re-check the checkbox.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR To edit the task, select it (see Figure #27 above) and click the Edit button or just double click on the task. The Edit task window will appear (see Figure #29 below) Figure # 29 To remove the task select it and click the Remove button (see Figure #27 above). You may select multiple tasks using Ctrl and Shift keys.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR HINT: Use the popup menu which can be activated by the right mouse button click over the table (see Figure #25 above). 7.3. Setting up application events Using the Application events window you can specify the socket events when a certain application is launched or closed down. You can also associate switching the sockets off or on with placement and removal of particular files in certain folders.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 30 To add a new program event, click the Add app button.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 31 Specify the application title and path to it using the Browse (…) button or typing it manually in the Title and Path name fields. If you use the Browse (…) button you can also select a shortcut to the application. In this case the application title and path name will be taken automatically via the shortcut if possible. After you have specified the application, check On run and/or On exit and choose the event (switch on or off).
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR NOTE: The On run event will take place when the first window of the selected application is opened. The On exit event will take place when the last window of the application is closed. HINT: Your device is an advanced standby-killer. Using this feature you can for example switch your scanner on/off whenever Photoshop is started/closed. To add a new file event, click the Add folder button (see Figure #30 above).
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Specify the path to the folder you would like to monitor using the Browse (…) button or typing it manually in the Path name field. Specify the File name mask using wildcard characters: *, ?. Check then On placing and/or On removal checkboxes and select the event and delay. NOTE: The On placing event will take place when the first file matching the specified file name mask is placed into the specified folder.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Figure # 33 To remove the event, select it and click the Remove button (see Figure # 30 above). You can select multiple events using Ctrl and Shift keys. You can also remove all events by clicking the Clear button HINT: Use the popup menu which can be activated by the right mouse button click over the table.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 8. Managing EG-PMS2-WLAN via your own software To let you switch the sockets from your own applications the following command line interface syntax is supported: pm.exe -[on | off] -device name -socket name Examples: "C:\Program Files\ Energenie\Power Manager\pm.exe" -on -My EnerGenie -Socket1 "E:\Utils\PM3\pm.exe" -off -My EnerGenie -Table lamp Execute pm.exe with -info key (pm.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Socket#SwitchState, where # is replaced by a certain socket number - TRUE, when the socket is switched on, FALSE, when the socket is switched off Socket#VoltageState, where # is replaced by a certain socket number - TRUE, when voltage presence on the socket is detected, FALSE, when there is no voltage on the socket; Example: NOTE: Each use of this command line option totally overrides the data in Info.ini file. NOTE: Power Manager should be active. 9.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR 10. Troubleshooting Problem The rocker switch turns off. The switching command is not carried out, the rocker switch and indicators are not lit. The status of EG-PMS2WLAN in Power Manager does not become Connected EG-PMS2-WLAN is connected to local network (ping test is ok) but not responding. Connection to EG-PMS2WLAN is lost. It seems something is wrong with its IP address.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR This product is tested and complies with the essential requirements of the laws of member states concerning R&TTE(1999/5/EC). The CE declaration can be found under www.gembird.eu Dieses Produkt wurde getestet und stimmt mit den grundlegenden Anforderungen der Richtlinie EMC(2004/108/EC) überein. Die Konformitätserklärung kann auf unserer Webseite www.gembird.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR Waste disposal: Entsorgungshinweise: Do not deposit this equipment with the household waste. Improper disposal can harm both the environment and human health. For Information about waste collection facilities for used electrical and electronic devices, please contact your city council or an authorized company for the disposal of electrical and electronic equipment. Werfen Sie dieses Gerät nicht in den Hausmüll.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR WARRANTY CONDITIONS GARANTIE BEDINGUNGEN The receipt must clearly list the date of purchase and the part number, in addition it should be printed. Keep the receipt for the entire warranty period since it is required for all warranty claims. During the warranty period the defective items will be credited, repaired or replaced at the manufacturer's expense.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR GARANTIE VOORWAARDEN CONDITIONS DE GARANTIE Op de aankoopbon moeten de aankoopdatum en productomschrijving duidelijk vermeld staan. Gelieve de aankoopbon de gehele garantieperiode te bewaren, deze is ten alle tijden benodigd voor alle garantie aanspraken. Tijdens de garantieperiode zullen alle gebreken verholpen of vervangen worden door de fabrikant d.m.v. reparatie, omruiling van het defecte onderdeel of het gehele apparaat.
EG-PMS2-WLAN PROGRAMMABLE WLAN SURGE PROTECTOR ГАРАНТИЙНЫЙ ТАЛОН 1. Гарантийное обслуживание предоставляется в течение срока гарантии, при наличии правильно и четко заполненного гарантийного талона, и изделия в полной комплектации. Серийный номер и модель изделия должны соответствовать указанным в гарантийном талоне. 2. Гарантийное обслуживание представляет собой бесплатное устранение всех неполадок (ремонт), или замену изделия на новое (аналогичное). 3.