Operation Manual

11
EN
FR
ES
IT
RU
SV
FI
Error Code Possible Cause Things to check Solution
E1
Power magnetic (motor)
controlled products only
1. Motor unable to get into
correct tension position.
Check if there is too much
tension on motor.
1. Turn computer on and
remove the motor plug
containing the tension
cable. Move resistance
level on computer to
maximum.
2. As soon as motor
reached maximum po-
sition, re-insert the plug
containing the tension
cable.
3. Re-adjust tension, if
needed to ensure maxi-
mum resistance.
4. Test all resistance levels.
5. Replace motor or
computer if the problem
persists.
E2 1. EEPROM chip on control
board has a bad
connection.
Check if the EEPROM chip is
plugged-in correctly.
Remove the EEPROM and
re-insert. If the problem per-
sists, replace control board.
2. The software stored in
the EEPROM chip on the
control board is
defective.
Replace control board.
E4 1. No pulse signal input
when using body fat
calculator.
Keep hands placed on
hand pulse plates until the
result is displayed.