WE'VE GOT YOU COVERED! Contact us by phone at 1-877-528-3772, email us at support@energizergenerators.com, or visit us online at www.energizergenerators.com. SAVE THESE INSTRUCTIONS - This user guide contains important instructions for your product, that should be followed during installation and mainteneance of the generator and batteries. This user guide covers the safety, operation and maintenance procedures for the EZV2200 and EZV2800.
WARRANTY INFORMATION YOU CAN REGISTER EASILY USING OUR ONLINE FORM: www.energizergenerators.com See Chapter 9 for more information. Product registration will allow you to request warranty support in the future. Product registration is required for all product support and warranty coverage. Warranty support, operation assistance and product support is provided by Midland Power Inc., a licensed manufacturer of Energizer Generators. Please contact us directly for any warranty service questions.
CONTENTS PAGE Safety First 8 Safety while using your generator 8 Understanding AC safety 9 Safety while maintaining your generator 9 Other safety tips 10 Learn About Your Generator 11 Identification of componants 11 Making sure you have everything 13 Setting Up Your Generator 14 Checking the oil level 14 Checking the air filter 15 Using Your Generator 17 Initial startup of your generator 17 Operating your generator 19 Shutting off your generator 21 Using your generator with a
Chapter 1 — Safety First Playing it safe when working with power equipment is always a good idea. Here are some important precautions to make sure you stay safe. 1.1 Safety while Operating Your Generator • Always perform an oil, fuel and air filter check before starting the engine. • Properly clean and maintain the equipment. • Operate the generator according to instructions for safe and dependable service. • Before operating the generator, read the user guide carefully.
operation. • Do not operate the generator in rain or snow. • Do not allow any moisture to come in contact with the generator. • Do not touch the spark plug while the engine is operating or shortly after the engine has been shut down 1.2 Understanding AC Safety Before connecting the generator to an electrical device or power cord: • Make sure that everything is in proper working order. Faulty devices or power cords can lead to an electrical shock.
• Do not clean the filter element with flammable liquids like gasoline because an explosion may occur. • Turn off the engine before performing any maintenance. Otherwise it can cause severe personal injury or death. • Allow the generator set to cool down before performing any maintenance. • Always wear safety glasses when cleaning the generator set with air. • Do not clean the generator set with a pressure washer because it can cause damage to the generator set.
Chapter 2 — Learn About Your Generator This section will show you how to identify key parts of your generator. Going over the terminology below will make sure we're on the same page. 2.
USB Outlet Output Light Overload Light Low Oil Light On/Off Ignition Switch AC Dual Outlet DC Reset 20A Circuit Breaker DC Outlet EcoMode Switch 120V 30A Outlet Ground EcoMode Switch Output Light On/Off Ignition Switch Overload Light Low Oil Light AC Dual Outlet DC Reset 20A Circuit Breaker DC Outlet 30A Circuit Breaker USB Outlet Ground 12
On Re Handlear 2.2 Make Sure You Have Everything Part Name Quantity EZV series Generator 1 User Guide 1 DC Charging Cables 1 450mL 10W30 Oil with Funnel 1 Tool Kit 1 Make sure your generator set has everything in the table above.
Chapter 3 — Setting Up your EZV series Generator Setup should be done every time you start up your generator, these quick checks will ensure you get the most out of your generator. Exhaust gas contains poisonous carbon monoxide. Never run the generator in an enclosed area. Be sure to provide adequate ventilation. Operate the generator on a level surface. If the generator is tilted, fuel spillage may result. Keep away from moving parts while the generator is running.
Gasoline substitutes are not recommended. They may be harmful to the fuel system components. Gasoline is highly flammable and explosive under certain conditions. Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow open flames or sparks in the area where the generator is being Maximum Oil LevelDo not overfill the tank. Be careful refueled or where gasoline is stored. Minimum Oil Level not to spill fuel when refueling.
Chapter 4 — Using Your EZV series Generator DANGER - CARBON MONOXIDE Using a generator indoors WILL KILL YOU IN MINUTES. Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell. If you can smell the generator exhaust you are breathing CO. Even if you can not smell the exhaust, you could be breathing CO. NEVER use a generator inside a home, garage, crawlspace, or other partly enclosed area, deadly levels of carbon monoxide can build up in these areas.
4.1 Initial Setup of Your Generator We know you're excited to get using your generator. Please be sure to follow the setup, operation, and shut off instructions below thoroughly to ensure the best lifespan for your generator. Steps 1-3 are for the EZV2800 only. If you have an EZV2200 start on Step 4. 1. Setup the Battery: Remove the Battery Access Panel from the unit by unscrewing the screw at the top and releasing the panel. 2.
5. Locate, unscrew, and remove the Oil Dipstick, exposing the internal engine compartment. Be sure not to allow any dust or debris near the engine during this time. 6. Pour in the full contents of the 450 mL oil bottle provided with your unit, or fill to the full mark located on the dipstick. 7. Re-install the Oil Dipstick and fasten tightly. Wipe away any excess oil. For best results, drain and refill the engine oil after the first 20 hrs of use, and every 50 hrs thereafter.
4.2 Operating Your Generator Before using generator, a ground wire must be connected to the ground terminal. The Ground terminal is located on the Front Panel. Before using the ground terminal consult a qualified electrician. 1. Disconnect all devices from the generator. 2. Open the fuel valve: turn the fuel valve from "off" to "on". Make sure the valve is turned all the way on. 3. Turn choke to "closed" position.
5a. (EZV2800 only, for EZV2200 proceed to step 5b) Turn Power switch to "Start" for 5 seconds to start engine. If the engine does not start, the battery may be dead, proceed to step 5b to start the engine. Running the engine charges the battery. 5b. Pull Recoil handle until engine starts. Several pulls may be required until engine starts. Do not release the pull cord at the end of a pull, this will damage the recoil assembly. Bring the pull handle back down to the unit by hand. 6.
4.3 Shutting Off Your Generator 1. Disconnect all devices from the generator. 2. Turn EcoMode switch to "Off". Let generator run with EcoMode off for 2 minutes. 3. Turn Power switch to "Off". 4. Close the fuel valve by turning it to "Off". To stop the engine in an emergency, turn the engine switch “OFF”. Always connect the ground terminal at the front panel to the ground (earth) to prevent electrical shock.
4.4 Using an EZV series generator with your Devices After starting your generator you can connect your devices to it. Before starting, make sure that you know what you are able to power with your Generator. Here's how you can find out: Add the watt ratings of all the loads that the generator set will be powering at the same time. Make sure that total wattage will not exceed the generator rating.
1. Connect the positive (red) terminal of the battery to the red (positive) terminal, the 12V 8.3A DC Output Terminal on the front panel of your generator. 2. Connect the negative (black) terminal of the battery to the black (negative) terminal, the 12V 8.3A DC output terminal on the front panel of your generator. Do not reverse the polarity of these connections. 3. Insert the DC plug into the DC receptacle. The generator should be running, and with EcoMode off. After insertion EcoMode may be turned on.
Chapter 5 — Maintaining Your EZV series Generator Proper maintenance ensures safe, economical and trouble-free operation. Improper maintenance may cause the generator to malfunction and can lead to serious injuries. Contact Energizer Power Customer Support if you have any maintenance questions. 5.
5.2 General Inspection Tips 1. Look for fuel leaks around the fuel tank, fuel hose, and fuel valve. Close the fuel valve and repair leaks immediately. 2. Look and listen for exhaust leaks while the engine is running. Have all the leaks repaired before continuing operation. 3. Check for dirt and debris and clean as necessary . 4. Check the engine oil level and add oil as necessary. Do not use gasoline or low flash point solvents for cleaning. They are flammable and could explode under certain conditions.
5.4 - Changing the Engine Oil Used motor oil can cause skin irritations if left in long-term contact with skin. Wash hands thoroughly with soap and water after handling oil. Do not dispose of used oil in drains or soil. Local service shops provide environmentally-friendly disposal methods. 1. Stop the engine and remove the oil access panel. 2. Place a pan beside the generator. 3.
5.5 - Replacing and Cleaning the Spark Plug Do not rinse spark plug in water. Follow guidelines and be careful not to overtighten the spark plug. Tighten ½ turn when installing a new spark plug. Tighten ¼ turn when re-installing an old spark plug. 1. Unscrew and remove spark plug access panel and screws. 2. Remove ignition coil from spark plug and remove spark plug with spark plug wrench. 3. Inspect the spark plug and clean any dirt from the electrodes with a wire brush.
5.6 - Handling and Storage Handling 1. Turn off the power switch and the fuel valve when transporting the generator set. 2. Do not touch engine until the engine has cooled down. 3. Keep the generator at a level position in order to prevent spillage. Storage Before storing the generator set for an extended period: 1. Ensure that the storage area is free of excess humidity and dust. 2. Drain the fuel tank and the carburetor. 3.
6.0 Troubleshooting Common issues can be fixed by following the instructions in this guide. If the unit will not function after following these instructions, contact technical support before attempting to use or repair the product. PROBLEM SYMPTOMS Generator will Generator will not start not start CORRECTION 3. The power switch is in the “Off” position. Switch to “On.” 4. The engine is out of gasoline, add more. 5. Engine choke is in wrong position.
Generator does not produce No indicator 1. Generator circuit breaker off or tripped lights or display 2. Remove all loads, reset breaker, and check device power on front panel for defects. Do not exceed generator rating. Generator does Overload 1. Adjust choke lever according to instructions on not produce indicator light power (cont.) keeps flashing page 20 2.
Engine idle 1. Carburetor in need of tuning. For details on how fluctuates to adjust correctly please contact your local service centre, or contact Midland Power Inc. at 1-877-528-3772. Missing ground reference on return side of differential analog output (external). 2. Air filter element obstructed by debris. Clean according to user manual instructions on page 25 Engine stops Engine idles 1. The power switch is in the “Off” position. down and 2. The engine is out of gasoline.
Chapter 7- Specifications EZV2200 EZV2800 60 60 Rated AC Output Power (W) 2000 2600 Max AC Output Power (W) 2200 2800 1-Phase Rated AC Voltage (V) 120 120 Power Factor 1.0 1.0 Max DC Output Power (W) 100 100 Rated DC Voltage (V) 12 12 GENERATOR Rated frequency (Hz) Type 3.80 HP, Single Cylinder, forced 5.
Chapter 8- Wiring Diagram 33
Chapter 9 - Learn About your Warranty Energizer Power Equipment Customer Support Center Toll Free: 1-877-528-3772 E-mail: support@energizergenerators.com Online: www.energizergenerators.com ENERGIZER POWER EQUIPMENT PRODUCTS ARE DISTRIBUTED BY: Midland Power Inc 376 Magnetic Drive, Toronto, ON M3J 2C4, Canada This product is warranted to be free of defects in material and workmanship for two years from date of purchase.
LIMITATION OF REMEDIES AND DISCLAIMERS Midland International Inc. disclaims any responsibility for loss of time or use of the generator in a recreational vehicle or any vehicle in which the generator is installed, transportation, commercial loss, or any other incidental or consequential damage. Any implied warranties are limited to the duration of this written warranty.
7. Items not supplied by Energizer, including, but not limited to, starting batteries, battery cables, external wiring, fuel lines, filters, etc; (refer to exclusions). 8. Repairs made during the warranty period, without first obtaining a case number from Energizer. Batteries supplied with any generator product should be considered a bonus item and not covered by warranty.
EMISSION CONTROL SYSTEM WARRANTY Your new Midland Power Inc. engine complies with the U.S. EPA (Environmental Protection Agency) regulations, State of California emission regulations (models certified for sale in California only) and Canada EPA regulations. Midland Power Inc. provides the emission warranty coverage for engines in the United States and its territories. Midland Power Inc. provides the emission warranty for engines in the 13 provinces and territories of Canada.
EMISSION CONTROL SYSTEM WARRANTY PARTS: Systems Covered in Parts Description Warranty Carburetor assembly (includes starting enrichment Fuel Metering system), Engine temperature sensor, Engine control module, Fuel regulator, Intake manifold Fuel Tank, Fuel Cap, Fuel Hoses, Vapor Hoses, Carbon Evaporative Canister, Canister Mounting Brackets, Fuel Strainer, Fuel cock, Fuel Pump, Fuel Hose Joint, Canister Purge Hose Joint Exhaust Catalyst, Exhaust Manifold Air Induction Air filter housing, Air filte
Warranty Registration Instructions: Ownership must be registered with Energizer Power Equipment in order to ensure continued warranty and service support. Please fill out the registration card below and mail it along with a copy of your receipt, and the original UPC barcode from your product packaging. The store, date of purchase and product purchase should be clearly visible on the receipt copy. YOU MAY ALSO REGISTER ONLINE BY VISITING OUR WEBSITE: www.energizergenerators.
Ownership and Warranty Transfer Instructions: Changes in ownership must be registered with Energizer Power Equipment in order to ensure continued warranty and service support. Warranty support cannot be provided without registration (from original date of purchase and after transfer of ownership) This transfer form must be completed on or before the date that ownership change takes effect. Warranty coverage continues from original date of purchase and is not extended by transfer of ownership.
Enjoy! Be sure to check energizergenerators.com monthly for updates regarding your generator.