Use and Care Manual

23
1. Connect the positive (red) terminal of the battery to
the red (positive) terminal, the 12V 8.3A DC Output
Terminal on the front panel of your generator.
2. Connect the negative (black) terminal of the battery
to the black (negative) terminal, the 12V 8.3A DC
output terminal on the front panel of your generator.
Do not reverse the polarity of these connec-
tions.
3. Insert the DC plug into the DC receptacle. The
generator should be running, and with EcoMode off.
After insertion EcoMode may be turned on.
An explosive hydrogen gas is discharged through vent holes in the battery during
charging. Do not allow sparks or open flames around the generator or battery
during the charging process.
Electrolyte fluid can burn eyes and clothing. Be extremely careful to avoid any
contact. If injured, wash the affected area immediately with large amounts of
water and seek medical attention immediately.
When charging a large capacity battery or totally discharged battery, excessive
current may force the DC breaker to turn off. In this case, use a battery charger.