SDS

Lithium ion battery - GSP0850110 5000mAh 3.7V
Safety Data Sheet
This document has been prepared in accordance with the SDS requirements of the OSHA Hazard Communication Standard 29 CFR 1910.1200
24/07/2019 EN (English US) 4/10
7.2. Conditions for safe storage, including any incompatibilities
Storage conditions : Store in a cool and dry area, but prevent condensation on cell or battery terminals.
High temperature may damage the performance of the battery.
Protect from physical damage and short circuits.
To avoid risk of fire or explosion, keep sparks and other sources of ignition away from the
battery.
Do not allow metal objects to simultaneously contact both positive and negative terminal of
batteries.
Do not stack battery directly on another battery.
Do not store batteries on electrically conductive surfaces.
Keep containers tightly closed in a dry, cool and well-ventilated place
Keep locked up and out of reach of children
Keep away from food, drink and animal feeding stuffs
Store in accordance with local regulations
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Graphite (7782-42-5)
ACGIH ACGIH TWA (mg/m³) 2 mg/m³ (all forms except graphite fibers-respirable
particulate matter)
OSHA OSHA PEL (TWA) (mg/m³) 15 mg/m³ (synthetic-total dust)
5 mg/m³ (synthetic-respirable fraction)
IDLH US IDLH (mg/m³) 1250 mg/m³
NIOSH NIOSH REL (TWA) (mg/m³) 2.5 mg/m³ (natural-respirable dust)
Phosphate(1-), hexafluoro-, lithium (21324-40-3)
Not applicable
Ethylene carbonate (96-49-1)
Not applicable
Diethyl carbonate (105-58-8)
Not applicable
Dimethyl carbonate (616-38-6)
Not applicable
Polypropylene (9003-07-0)
Not applicable
Iron (7439-89-6)
Not applicable
Copper (7440-50-8)
ACGIH ACGIH TWA (mg/m³) 0.2 mg/m³ (fume)
OSHA OSHA PEL (TWA) (mg/m³) 0.1 mg/m³ (fume)
1 mg/m³ (dust and mist)
IDLH US IDLH (mg/m³) 100 mg/m³ (dust, fume and mist)
NIOSH NIOSH REL (TWA) (mg/m³) 1 mg/m³ (dust and mist)
0.1 mg/m³ (fume)
Aluminum (7429-90-5)
ACGIH ACGIH TWA (mg/m³) 1 mg/m³ (respirable particulate matter)
OSHA OSHA PEL (TWA) (mg/m³) 15 mg/m³ (total dust)
5 mg/m³ (respirable fraction)
NIOSH NIOSH REL (TWA) (mg/m³) 10 mg/m³ (total dust)
5 mg/m³ (respirable dust)
Cobalt lithium manganese nickel oxide (182442-95-1)
Not applicable