User manual

Upon above display, continuously press the DOWN key will lead the LCD to display the total accumulated
electricity cost spent from the pairing, the energy consumption and CO2 emission (unit: kgs) for current day, the
electricity cost spent for current day, the energy consumption and CO2 emission for current month, the electricity
cost spent for current month, respectively and in turn, as below photos. Press the OK during this viewing will return
the LCD to the Default Display. Idleness of key operation for 60seconds will also return to Default Display.
Buzzer Setting
Upon the Default Display, press at the same time UP key and DOWN key and hold them there for about 3 seconds
until the LCD screen displays the Buzzer status. bOFF means the Buzzer is off. bON means the Buzzer is on.
Press the UP/DOWN key to switch the Buzzer status. Press OK key to exit setting. If key operation is idle for 60
seconds, the setting will exit automatically without saving.
Temperature
The temperature that can be displayed on the screen is -9~50. For temperature under -9, the temperature will
display as LO. For temperature over 50, the temperature will display as HO. The temperature accuracy is
±2.
Electricity Tariff Setting
1 Currency Setting: Upon the Default Display, press the UP key and hold it for 3 seconds until the currency
symbol flashes. Press the UP/DOWN key to select the desired currency symbol. Press the OK key to confirm.