Instruction Manual

SAFETY FIRST
L1680
Rev. C
02/98
®
A UNIT OF APPLIED POWER INC.
Instruction Sheet
SC-1 Swing Clamps
IMPORTANT RECEIVING INSTRUCTIONS: Visually inspect all components for shipping dam-
age. If any shipping damage is found, notify carrier at once. Shipping damage is NOT covered
by warranty. The carrier is responsible for all repair or replacement cost resulting from dam-
age in shipment.
Carefully plan your system by selecting components designed to perform the intended opera-
tion and which will adequately perform with existing equipment. Always check the product limi-
tations regarding pressure ranges, load capacities and set-up requirements. The system oper-
ating pressure must not exceed the pressure rating of the lowest rated component in the sys-
tem. Read all CAUTIONS, WARNINGS and INSTRUCTIONS included with, or attached to,
each product. Follow all safety precautions to avoid personal injury or property damage during
the system operation. ENERPAC CANNOT BE RESPONSIBLE FOR DAMAGE OR INJURY
RESULTING FROM UNSAFE USE OF PRODUCT, LACK OF MAINTENANCE, OR INCOR-
RECT PRODUCT AND SYSTEM APPLICATION. Contact ENERPAC when in doubt as to
safety precautions, or applications.
Description
Enerpac SC-1 swing clamps can be set for left swing,
right swing, or straight pull operations. Swing cylinders
rotate 90° during the first portion of the stroke, contin-
uing without rotation for the final clamping stroke.
Swing cylinders can be operated as either single act-
ing or double acting. SC-1 cylinders come with a
retract spring for single acting operation. A standard
clamp arm is supplied with cylinder.
Specifications
Operating Pressure: 3000 PSI maximum
Maximum Frequency: 40 Cycles/Minute
Swing Arc: 90°
Seal Material: Buna-N/Polyurethane/Molythane
STROKE Initial Clamping Total
1.00” 0.50 1.50”
Figure 1: SC-1 Swing Clamps