O-888 Commercial Air Purifier 1
OWNER’S MANUAL Please read all of the information provided in this owner’s manual before operating your new Enerzen commercial air purifier.
CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN ATTENTION CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVCE PERSONNEL. This “bolt of lightning” indicates that uninsulated material within your unit may cause an electrical shock. For the safety of everyone, do not remove the product covering.
Read ALL instructions carefully before using this product. Model: O-888 Rated Voltage: USA/Japan AC 100-120V/50-60Hz Power Consumption: 100 W Ceramic Plate Size(1plate): 90X110MM Air Volume: Max 100 CFM(2.8 M /min) Sound Level(DB): 35 Db Product size(mm): W178xH148xD205MM Weight: 2.39Kgs(5.
Operating the Commercial Purifier (Front View) Timer Control Knob Turn clockwise to set the timer for timed operation up to two hours. Indicator Light Illuminates when the unit is in operation.
(Back View) Fuse Holder Houses removable fuse. (Spare fuse included, 2 amp, 0.
The Enerzen Commercial Ozone Generator and Air Purifier is designed to remove odors in unoccupied spaces. The unit has a timer that will enable it to run for a maximum duration of 2 hours. The timer will then shut the unit off. You should allow 40-60 minutes before returning to the treated area. We recommend an initial treatment time of 15-30 minutes to see if that is sufficient to remove odors followed by longer treatment times if necessary.
When the air purifier no longer produces enough ozone to be effective, the ozone plate should be replaced. How to replace a plate: 1) Turn the unit off and unplug from outlet. 2) Use a screw driver to unfasten cover screw and remove cover. 3) Pull ceramic plate out of ozone generator module.
4) Install ceramic plate as shown in left figure (be careful not to drop the plate). If you suspect a problem with your unit check the following: 1) Unit is plugged in properly. 2) It’s important that the air purifier be properly grounded to avoid potential shock. 3) Fuse is installed properly and in good condition. To replace fuse, pull out the plastic fuse holder, remove old fuse and insert new fuse. Replacement fuse must be 2 amp (0.79 inch).
Warranty Information OION Technologies, LLC (collectively “OION”) warrants from the date of purchase, this product will be free from defects in material and workmanship. Please refer to your retailer’s product page for the duration of the warranty. OION, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component.