Specifications

14 Euromax Pellet Stove Installation and Operation Manual
4.2 Recommendations
In Canada, we recommend that you use a listed pellet vent that meets the CAN/ULC S609 or
ULC/ORD C441 Standard. A pellet vent listed to ULC S629M is also suitable for installation
with this stove.
For the United States, we recommend that you use a listed pellet vent that meets the UL 641
Standard. A pellet vent listed to UL 103 is also suitable for installation with this stove.
This stove can be vented in an existing factory-built or masonry chimney with the addition of a
stainless steel liner, provided the chimney is more than 4” in diameter. The liner should be
listed and should meet the ULC S635 CAN/ULC S640 standard in Canada and the UL 1777
standard in the USA. Refer to the instructions provided by the vent manufacturer, especially
when passing through a wall, ceiling or roof.
4.3 Equivalent Vent Length (EVL)
Recommended venting system inner pipe diameter is 4”.
To calculate the EVL of your installation, use the following conversions:
Qty Type of pipe EVL equivalent(ft)
1 90° elbow or “T” 5
1 45° elbow 3
1 ft Horizontal pipe run 1
1 ft Vertical pipe run 0.5
NOTE: Horizontal runs shall not exceed 9 feet.
NOTE
Here is an example to help you calculate Equivalent Vent Length. On the following figure the
EVL can be calculated like this:
: Never exceed 30 feet of EVL.