United States:
Not Less than 36’’ (91 cm) above any forced air inlet located within 10 feet (305 cm);
Not Less than 48’’ (122 cm) below and horizontally from, or one foot (30 cm) above, any
door, window or gravity air inlet into any building;
Not Less than 24’’ (61 cm) from an adjacent building and not less than 84’’ (213 cm)
above grade when located adjacent to a public walkway.
Cannot be located less than 12 inches (300mm) above grade.
Cannot be located above a gas meter/regulator within 3 feet (900mm) horizontally of the
vertical center line of the regulator.
Not within 6 feet (1.8 m) of a gas service regulator vent outlet.
Other restrictions may apply. See NFPA 211 for further information.
4.5 Installation Configurations
4.5.1 Installation Warnings, Cautions and Recommendations Reminder
PROFESSIONNAL INSTALLATION IS HIGHLY RECOMMENDED
THIS STOVE USES A PRESSURIZED VENTING SYSTEM. ALL VENT CONNECTOR
JOINTS MUST BE SEALED AND FASTENED. CONSULT THE PELLET VENT
MANUFACTURER’S INSTRUCTION TO ENSURE PROPER INSTALLATION,
CONSISTENT PERFORMANCE, AND TO AVOID SMOKE AND ASH SPILLAGE.
USE RTV SILICONE (Room Temperature Vulcanisation), METALLIC TAPE, AND A
MINIMUM OF THREE SELF-TAPING SCREWS AT ALL JOINT CONNECTIONS TO
ENSURE A TIGHT SEAL.
THE CHIMNEY CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR ROOF
SPACE, CLOSET OR SIMILAR CONCEALED SPACE OR FLOORS OR CEILING.
INSTALL VENTING SYSTEM AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
THE USE OF A SPARK ARRESTER AT THE END OF THE TERMINATION IS
MANDATORY.