Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ User Guide GSM1308UG001 Revision: 1.03 6/1/2009 www.enfora.
GENERAL TERMS OF USE OF NEW MATERIALS - PLEASE READ CAREFULLY From time to time, Enfora, in its sole discretion, may make available for download on its website (www.enfora.com), or may transmit via mail or email, updates or upgrades to, or new releases of, the firmware, software or documentation for its products (collectively, 'New Materials').
LIMITED WARRANTY SCOPE Enfora warrants to the original purchaser of the product that, for a period of one (1) year from the date of product purchase, the product hardware, when used in conjunction with any associated software (including any firmware and applications) supplied by Enfora, will be free from defects in material or workmanship under normal operation.
SOFTWARE During the warranty period applicable to the software or its media, Enfora, at its expense, will replace any defective software or media if purchaser gives written notification of the defect to the technical support department at Enfora during the applicable warranty period. Enfora will ship or otherwise transmit the replacement software or media to purchaser, and purchaser shall be responsible for incorporating any replacement software in the product.
OTHER CONSIDERATIONS Some jurisdictions may require a longer warranty period than specified above and, accordingly, for products sold in those jurisdictions the applicable warranty period shall be extended as required under the laws of those jurisdictions.
mobile transmitters and MPE (Maximum Permissible Exposure) requirement of General Population/Uncontrolled exposures. RF EXPOSURE Your GSM1308 or GSM1318 SA-G+ modem is a radio transmitter and receiver. It is designed and manufactured not to exceed the emissions limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission (FCC) of the U.S. Government. These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population.
of the guidelines contained herein. Said variables must be taken into consideration when installing or using the product, and Enfora shall not be responsible for installations or transmissions that fall outside of the parameters set forth in this publication. User Guide P a g e VI Revision: 1.
TABLE OF CONTENTS General ............................................................................................................................ 1 COPYRIGHT .................................................................................................................... 1 LIMITED WARRANTY ....................................................................................................... 2 SCOPE .....................................................................................................
2.2.2 GPIO2 (Input/Output) Programmable Pull-Up System ..................................... 8 2.2.2.1 2.2.2.2 2.2.2.3 GPIO 2 Electrical Specifications .................................................................................. 8 GPIO2 as Pull-Down System ...................................................................................... 8 GPIO2 as a Pull-Up System........................................................................................ 8 2.3 Connecting the Serial Cable .......
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 1 Introduction 1.1 ABOUT THE GSM/GPRS SA-G+ The GSM/GPRS SA-G+ is a compact, stand-alone wireless IP (GSM/GPRS) modem. The GSM/GPRS SA-G+ is designed for computing devices operating Windows XP and Windows 2000 or any serial-enabled platform. The SA-G+ can be used as a stand-alone serial device with other vertical applications.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ GSM0000AN009 - Dynamic IP Assignment Support GSM0000AN011 - PAD Configuration and Use GSM0000AN012 - Network Transparency Configuration for PAD GSM0000AN013 - Enabler-G Sleep Mode Configuration and Use GSM0000AN014 - Anytime PPP API Access GSM0000AN015 - Event Monitor and Reporting Overview GSM0000AN016 - How to Send SMS Messages to an E-Mail Address GSM0000AN017 - SMTP Mail Access via TCP PAD GSM0000AN018 - USNO NTP Network Time Service TCP PAD GSM0000AN01
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 1.4 SA-G+ FRONT AND BACK VIEW Figure 1 - Front view of GSM/GPRS SA-G+ modem. Figure 2 - Rear view of GSM/GPRS SA-G+ modem. User Guide Page 3 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 2 Installation 2.1 SUBSCRIBER IDENTITY MODULE (SIM) CARD The SIM, an integral part of any GSM terminal device, is a “smart card” that is programmed with subscriber information. The user information consists of an International Mobile Subscriber Identity (IMSI) number, which is registered with the GSM service provider, and an encryption Ki (pronounced “key”). This information consists of a microprocessor and memory installed on a plastic card.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 2.2 EIGHT (8) PIN CONNECTOR The GSM/GPRS SA-G+ modem can utilize input power ranging from 6 Vdc to 40 Vdc.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ During installation take precautions to help ensure proper operation of the SA-G+. Do not create loops, sharp bends or crimps in the cables. Use proper terminations on all power cables. Note: : If the SA-G+ will be used in a vehicle, attach all cables to the vehicle and equipment in such a way to reduce stress or wear caused by vibration generated by moving vehicles.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ Figure 4 Molex Connector and Pins 2.2.1 GPIO1 (INPUT/OUTPUT) 2.2.1.1 GPIO 1 ELECTRICAL SPECIFICATIONS • Input VIH: >2.2 V • Input VIL: <1 V • Output VOH: 3 V • Output VOL: 0 • Max Source Current: Approximately 350 μA • Max Sink Current: 3.7 mA @ 40 V, 0.13 W 2.2.1.2 GPIO1 AS AN INPUT Set the bus direction to be “input” by using the “AT$IOGP1=1” command. Verify that GPIO1 is set to be an input by using the “AT$IOCFG?” command. 2.2.1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 2.2.2 GPIO2 (INPUT/OUTPUT) PROGRAMMABLE PULL-UP SYSTEM 2.2.2.1 GPIO 2 ELECTRICAL SPECIFICATIONS • Input VIH: >2.2 V • Input VIL: <1 V • Output VOH: 3 V • Output VOL: 0 • Max Source Current: Approximately 320 μA • Max Sink Current: 3.7 mA @ 40 V, 0.13 W 2.2.2.2 GPIO2 AS PULL-DOWN SYSTEM Set GPIO2 to 0 by using the “AT$IOPULUP=0” command. 2.2.2.3 GPIO2 AS A PULL-UP SYSTEM Set GPIO2 to 1 by using the “AT$IOPULUP=1” command.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ The following table provides the power characteristics of the GSM/GPRS SA-G+ modem. Band Mode Avg (mA) Peak (A@dBm) GSM 850 1 TX/1 RX 200 1.30@33 EGSM 900 Idle 50 DRX 5 DCS 1800 1 TX/1 RX 160 PCS 1900 Idle 50 DRX 5 Sleep 20 0.92@30 Table 3 GSM Operating Power Warning: Use of the device outside of the specified voltage range may result in damage to the device and/or undesirable results. User Guide Page 9 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 2.3 CONNECTING THE SERIAL CABLE To connect the SA-G+ with a local computing device, connect one end (male end) of the 9-wire RS232 Serial Cable to the SA-G+ port labeled "Serial" and connect the other end to a computer. The following figure provides the SA-G+ serial pin-out information. Figure 5- Serial Pin-out User Guide P a g e 10 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 2.4 CONNECTING THE GSM/GPRS ANTENNA The antenna is supplied by the user. The antenna must have a nominal impedance of 50 Ohms. The VSWR must be less than 2.0:1. System antenna gain should be 0-2 dB for optimum performance. The GSM/GPRS SA-G+ operates at the 850/900/1800 and 1900 MHz frequency bands. Care needs to be taken when connecting the antenna since the right type of antenna will be required for proper operation of the modem.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 2.5 LED FUNCTIONS The GSM/GPRS SA-G+ modem has one green LED on the front panel. REG: Indicates GSM network registration status. Flashing when attempting to register on a GSM network. Solid when the modem is registered with a GSM network. 2.6 MOUNTING THE SA-G+ The GSM/GPRS SA-G+ includes two mounting options. The modem housing contains four thru holes that can utilize number 2 screws for securing the device.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 3 Firmware Upgrade To see if there is updated firmware for the SA-G+, please visit: http://www.enfora.com > support You will need to obtain a login to the website from Enfora Tech Support in order to download the firmware.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 4 Configure the Computer and Verify Correct Communications Note: The following examples use Windows 2000 and HyperTerminal. Any Terminal program should work, using the parameters in Step 1 1. Default Serial Parameters a. b. c. d. e. Autobaud (power up message at115200 baud rate) 8 data bits 1 stop bit No Parity Flow Control = None 2. Determine which Com port to use f. On older computers, there is usually a built in Com port. This is normally Com1. g.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ i. User Guide Select the Device Manager button. Expand the Ports section by selecting the + sign beside Ports. Your window should look like the following: P a g e 15 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ j. Plug in the USB-to-Serial converter. The window should change to show the USB-to-Serial converter installed. k. Most devices will show the Com port next to the device name. Record this number. In this case, it is COM12. Note: Make sure there is no "!" or "X" next to the USB device. If you see an "!" or an "X," the device is not properly installed and will not work User Guide P a g e 16 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 3. Start HyperTerminal On Windows 2000, click on: Start>Programs>Accessories>Communications>HyperTerminal l. You should see the following screen. m. Enter a name for the Connection. In this example, the Name is Enfora Com1. n. Click OK. o. The next window that will appear is the Connect To window. User Guide P a g e 17 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ p. Change the Connect Using setting to the Com port that was determined in Step B. q. Click OK. r. The next window is the Port Settings window. User Guide P a g e 18 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ s. Make sure the settings match the example. t. Click OK. u. Now the Main Program Window should appear. User Guide P a g e 19 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 5 Configure the SA-G+ to talk to the Enfora Server 4. Connect and verify Serial connectivity with the Enfora SA-G+. v. Connect the PC serial connector to the SA-G+ serial port. Note: In the following instructions, means using the Enter Key on the keyboard With HyperTerminal open, hit the Enter key. The SA-G+ should respond with OK. If you do not see this response, double-check your connections. w. Type AT. The SA-G+ should respond with OK.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 5. Configure the SA-G+ to communicate with the Enfora Test Server. y. The following information will need to be obtained from the SIM provider. Please refer to GSM0000AN019 – Network Configuration Worksheet. z. APN aa. Username and password (If necessary.) Note: : In the following examples, the SIM is for Cingular. APN = isp.cingular Username = ISP@CINGULARGPRS.COM Password = CINGULAR1 bb.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ cc. Configure the SA-G+ to Access the GPRS network. To inform the SA-G+ of the proper APN, send the following command: AT+CGDCONT=1,”IP”,”apn” (substitute the letters apn for the supplied apn.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ Verify GPRS activation by sending the following command: AT$NETIP? If the response is non-zero, then everything is working. Skip to Step 10. User Guide P a g e 23 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ If AT$NETIP returns all zeros, send the following command: AT$CGEER There are three common responses: • • • • $CGEER: no PDP reject cause (Everything should be working OK) $CGEER: requested service option not subscribed (APN is incorrect or SIM has not been enabled for data mode.) $CGEER: user authentication failed (username and/or password is incorrect.) Configure the SA-G+ to access the Enfora Server.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ Configure the SA-G+ to talk with a specific server. • Send the following command: AT$FRIEND=1,1,”apitest.enfora.com” Set the port number • Send the following command: AT$UDPAPI=,1721 Enable periodic messages (wakeup) to be sent to the server every 60 seconds • User Guide Send the following command: AT$WAKEUP=1,1 P a g e 25 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 6 Verifying Server Connectivity Note: For the following tests, Java Runtime must be installed on the computer. (To install Java Runtime, please visit the Java website here: http://www.java.com/en/download/manual.jsp) 6. Start Internet Explorer and enter the following URL: http://apitest.enfora.com/udpapp/ 7. Enter the name used in the MDMID command in the box. Select Connect. 8. Select the tab with the SA-G+ name.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 9. Enter the following command in the command/ data block: ATI 10. Select Write. 11. Verify that you see the following the SA-G+ response with Enfora, Inc. If so, you have successfully configured the SA-G+ to talk with the server. User Guide P a g e 27 Revision: 1.
Enfora GSM1308 and GSM1318 Quad-Band Spider® SA-G+ 7 Tech Support For problems stemming from your network access, contact your GSM/GPRS carrier service. For technical support and customer service dealing with the modem itself, contact the company where you purchased the product. If you purchased the product directly from Enfora, visit the Support and Resources page on the Enfora website: http://www.enfora.com. User Guide P a g e 28 Revision: 1.