Manual
Alarm Messages on LCD Screen
1. Alarm - Over Temperature. Smart charger has exceeded safe temperature limit.
2. Alarm - Reverse Polarity. Battery is connected in reverse polarity (only shows when
mains power is connected).
3. Alarm - Open Circuit. Battery is not connected or is faulty (only shows when mains
power is connected).
4. Alarm - Low Battery. Battery voltage is low (less than 10.5V). The Engel Smart
Battery Box screen will switch off after 5 minutes however the discharge process
will continue if you leave a device connected. The Engel Smart Battery Box cannot
disconnect your device.
5. Alarm - Check battery. Battery won’t reach 12.8V within 25 hours. Battery may have
a problem (eg may be heavily sulphated or have a faulty cell). This alarm may be
triggered if the battery is being used to power a device and is being charged at the
same time, in which case the battery is OK.
6. Alarm - Low input voltage. Input voltage is below limit required to power charger.
Installing the Engel Smart Battery Box as part of a Dual Battery System
using the Anderson Plug
The Engel Smart Battery Box can be used in a dual battery set-up. The best method
to do this is to connect the Engel Smart Battery Box to a dual battery wiring loom (not
supplied) using either the positive/negative external terminals or the Anderson plug.
Using these methods the smart charge system is bypassed so the Engel Smart Battery
Box cannot control the charging voltage. A voltage sensitive relay/solenoid must be
used to ensure priority is given to charging the vehicle’s main starting battery. The
main isolator switch on the Engel Smart Battery Box must be switched on. The main
data screen will show “external cycle” after a few minutes of charging in this case. See
FAQs for more information.
Select Battery
CAPACITY
100 Amp Hour
110 Amp Hour
120 Amp Hour
130 Amp Hour
Select Battery TYPE
Lead Acid Battery
Gel Battery
Calcium Battery
AGM Battery
CALCIUM Battery
selected are you sure?
NO
YES
ARKPAK MODEL ACDC7
NO
YES
Have you installed a new battery?
Voltage
12.0V
TEMP: 22c
TYPE: Calc
CAP: 100 A/Hr
10% Charge
Step 3. Battery confirmation – CALCIUM batteries only
If you selected CALCIUM battery you will be asked to confirm your selection. Calcium
batteries need to be charged at a much higher voltage which could cause damage to
other battery types.
- Select YES if you are charging a CALCIUM battery – Proceed to step 4
- Select NO return to Battery type selection
Step 4. Battery Capacity Selection
Using the MENU buttons, scroll up or down to your battery size in Ah (amp hours) rating
and press OK to select. If your battery Ah rating is not listed then select the next level
down i.e battery size 105Ah – select 100Ah
Your battery setup is now complete and the main data page will appear. The charge
process for your specific battery chemistry will commence in 30 seconds.
These settings are now saved in the Engel Smart Battery Box. Please note the next time
you turn the Engel Smart Battery Box on the welcome screen is bypassed and the main
data screen will appear.
If you disconnect the saved battery or connect a new battery the welcome screen will
appear first (refer to step 1) and you’ll need to select ‘yes’ or ‘no’ again.
CAUTION – the Engel Smart Battery Box only saves the last battery setup, the setup
process will have to be completed every time a different battery is charged
WARNING – Do not charge battery using Anderson plug and car charging lead (refer
to page 2) at the same time.
Mounting the Engel Smart Battery Box
Engel offer an optional mounting kit for the Engel Smart Battery Box (Part no. TSLBATTBOX)
so it can be mounted onto a Transit Slide Lok. The Transit Slide Lok is mounted into the
vehicle. See www.engelaustralia.com.au for details of Transit Slide Lok and mounting kit.
Page 6