Table of Contents Chapter 1 Product Overview............................................... 4 Key Features/Introduction........................................................ 5 System Requirements............................................................... 6 Package Contents......................................................................... 7 Technical Specifications.............................................................. 8 Physical Interface.................................................
Chapter 1 Product Overview 4
Introduction Key Features • Supports IEEE802.11ac/a/n wireless standards with up to 867 Mbps data rate. • Internal 15.5dBi high gain directional antenna(EnStation5ACv2/EnStationACv2);Internal 13.42dBi high gain directional antenna(ENS500-ACv2); • External 5.
ACv2/EnStationACv2/ENS500-ACv2/ENS500EXT-ACv2 supports the 5 GHz frequency band for communicating to other 5GHz frequency bands Access Points concurrently. Several EnStation5-ACv2/EnStationACv2/ENS500-ACv2/ ENS500EXT-ACv2s can be networked in a campus setting using the 5 GHz band between countries, which is easy to be installed in virtually any location with its included PoE (Power over Ethernet) Adapter for quick outdoor installation.
System Requirements • Quick Installation Guide *(all items must be in package to issue a refund): The following are the Minimum System Requirements in order to configure the device. • Computer with an Ethernet interface or wireless network capability • Windows OS (XP, Vista, 7, 8, 10), Mac OS, or Linux-based operating systems The ENS500-ACv2/ENS500EXT-ACv2 package contains the following items:* • Web-Browsing Application (i.e.
Technical Specifications Standard: IEEE802.11ac wave2/a/n on 5 GHz Operation Modes-EnJet disable Access Point Client Bridge WDS AP WDS Bridge WDS Station Antenna Internal 15.5dBi high gain directional antenna (EnStation5-ACv2/ EnStationACv2) Internal 13.42dBi high gain directional antenna (ENS500-ACv2) External 2*5.
Reinforcement Security WPA2 Enterprise Hide SSID in beacons MAC address filtering, up to 32 MACs per SSID Wireless STA (Client) connection list Https Support SSH Support QoS (Quality of Service) Complaint with IEEE 802.
Physical Interface-EnStation5-ACv2/EnStationACv2 Dimensions and Weights EnStation5-ACv2/EnStationACv2 Dimension: 190mm (7.48”) Height: 38mm (1.9”) Weight: 527g (1.16 lbs) 1 WLAN Signal LED: Applied on Client Bridge/WDS (1) Red: Weak Signal: Connecting quality is bad. (2) Yellow: Connecting quality is Normal. (3) Green: Connection quality is Good. 2 LAN(PoE) Signal LED 3 LAN Signal LED of the 2nd Port 4 Power Signal: 5 LAN Port 1: Gigabit Ethernet port for RJ-45 cable.
Physical Interface - ENS500-ACv2/ENS500EXT-ACv2 Dimensions Length: 186 mm (7.32”) Width: 100 (3.94”) Depth: 29mm (1.14”) 1 5 GHz Antennas Detachable 5 dBi 5 GHz Omni-directional Antennas (ENS500EXT-ACv2 Only) 2 LAN Port 1 (Proprietary24V PoE): Ethernet port for RJ-45 cable. 3 LAN Port 2 : Ethernet port for RJ-45 cable. 4 LED Indicators: LED lights for Power, LAN Port 1, LAN Port 2, 2.4 GHz Connection and 5 GHz Connection.
Chapter 2 Before You Begin 12
Computer Settings Windows XP/Windows 7/Windows 8/Windows 10 1b. Move your mouse to the lower right hot corner to display the Charms Bar and select the Control Panel in Windows 8 OS. In order to use the Access Point, you must first configure the TCP/IPv4 connection of your Windows OS computer system. 1a. Click the Start button and open the Control Panel Windows 8 1c. In Windows 10, click Start to select All APPs to enter the folder of Windows system for selecting Control Panel.
4. Select Internet Protocol Version 4 (TCP/IPv4) and then select Properties. 2a. In Windows XP, click Network Connections. 2b. In Windows 7/Windows 8/Windows 10, click View Network Status and Tasks in the Network and Internet section, then select Change adapter settings. 3. Right click on Local Area Connection and select Properties. 5. Select Use the following IP address and enter an IP address that is different from the Access Point and Subnet mask, then click OK.
Note: Ensure that the IP address and Subnet mask are on the same subnet as the device. For example: ENH220EXT IP address: 192.168.1.1 PC IP address: 192.168.1.2 – 192.168.1.255 PC Subnet mask: 255.255.255.
Apple Mac OS X 4. In Configure IPv4, select Manually. 1. Go to System Preferences (Which can be opened in the Applications folder or selecting it in the Apple Menu). 5. Enter an IP address that is different from the Access Point and Subnet mask then press OK. 2. Select Network in the Internet & Network section. Note: Ensure that the IP address and Subnet mask are on the same subnet as the device. For example: ENH900EXT IP address: 192.168.1.1 PC IP address: 192.168.1.2 – 192.168.1.
Hardware Installation EnStation5-ACv2/EnStationACv2 1. Remove the rear bottom panel. 2. Connect one end of the Ethernet cable into the main LAN port (PoE) of the Access Point and the other end to the AP Ethernet port on the PoE Adapter. 3. Connect the Power cord to the PoE Adapter and plug the other end in to an electrical outlet. 4. Connect the second Ethernet cable into the LAN port of the PoE Adapter and the other end to the Ethernet port on the computer. 5.
Mounting the EnStation5-ACv2/EnStationACv2 Using the provided hardware, the EnStation5-ACv2 can be attached to a wall or a pole. 1. ETD 5. Screw Set Kit 2. PoE Adapter& Power Cord 3. Bracket 4. Pole Mounting Strap 6. Sealing Nut 7. Dynamic Stick 8.
Wall mounting the EnStation5-ACv2/ 5. Assemble t he mounting parts to the EnStation. . EnStationACv2 6. Determine the mounting location. Mark and drill two pilot holes aligning to the screw holes of the bracket 1. Put the included rubber into the bracket. 7. Put wall anchors into the holes and insert screw into the wall anchor. 2. Plug the dynamic stick into the bracket. 3. Screw the sealing nut and assembled parts, as well as tighten it. 8. Screw and secrue the bracket in the place. 4.
Pole mounting the EnStation5-ACv2/ 5. Assemble t he mounting parts to the EnStation. . EnStationACv2 1. Put the included rubber into the bracket. 6. Thread the open end of the pole strap through the two tabs on the bracket. 2. Plug the dynamic stick into the bracket. 7. Lock and tighten pole strap to secure bracket to the pole 3. Screw the sealing nut and assembled parts, as well as tighten it. 4. Put the nock washer on the dynamic stick.
Hardware Installation ENS500-ACv2/ENS500EXT-ACv2 1. Connect one end of the Ethernet cable into the LAN port (PoE) of the AP/ Bridge and the other end to the PoE port on the PoE adapter. This diagram depicts the hardware configuration. 2. Connect the Power cord with the PoE Adapter and plug the other end into an electrical outlet. 3. Connect the second Ethernet cable into the LAN port of the PoE adapter and the other end to the Ethernet port on the computer. 4.
Mounting the ENS500-ACv2/ENS500EXT-ACv2 Using the provided hardware, the ENS202EXT can be attached to a wall or a pole. The height should not exceed 2 meter. 1. Wall Mounting Kit 2. Pole Mounting Strap (Φ66*12.6 mm) (Anchors: Φ5.
To attach the ENS500-ACv2/ENS500EXT-ACv2 to a wall using wall mounting kit. To attach the ENS500EXT-ACv2 to a pole using the provided pole mounting kit: A. Determine where the Access Point to be placed and stick the Adhesive label on the surface. A. Thread the open end of the Pole Strap through the two tabs on the Pole Mount Bracket. B. Use the appropriate drill bit to drill two 8.1mm diagram and 26mm depth holes on the markings of the label. B.
Chapter 3 Configuring Your Access Point 24
Configuring Your Access Point 2. The default username and password are admin. Once you have entered the correct username and password, click the Login button to open the web-base This section will show you how to configure the device using the web-based configuration interface. Default Settings configuration page. Please use your Ethernet port or wireless network adapter to connect the Access Point. IP Address 192.168.1.1 Username / Password admin / admin Web Configuration 1.
Chapter 4 Building a Wireless Network 26
Before starting to configure this Access Point, you may realize the used scenario under varied operating modes. The EnStation5-ACv2/EnStationACv2/ENS500-ACv2/ENS500EXT-ACv2 is built in EnGenius EnJet solution, AP can transmit data more efficiently, avoid collisions,and reduce latency and packet losses. When EnJet enable, it can be configured as an: Access Point, Client Bridge or WDS (AP & Station) or Access Point, Client Bridge or WDS (AP, Station & Bridge) when EnJet disable.
Client Bridge Mode The AP/CPE essentially acts as a wireless adapter that connects to an access point to allow a system of wireless access to the network in the Client Bridge mode. Since the computers are on the same subnet, the AP/CPE can broadcast to reach all end-devices. If you use the client bridge mode in the AP/CPE, you can use the AP Detection feature to scan for Access Points within range.
WDS AP Mode The AP/CPE also supports WDS AP mode. This operating mode allows wireless connections to the AP/CPE using WDS technology. In this mode, configure the MAC addresses in both Access Points to enlarge the wireless area by enabling WDS Link settings. WDS supports up to four (4) AP MAC addresses.
WDS Bridge Mode In WDS Bridge Mode, the AP/CPE can wirelessly connect different LANs by configuring the MAC address and security settings of each AP/CPE device. Use this mode when two wired LANs located a small distance apart want to communicate with each other. The best solution is to use the AP/CPE to wirelessly connect two wired LANs, as shown in the following diagram. WDS Bridge Mode can establish up to four WDS links, creating a star-like network. Note: WDS Bridge Mode does not act as an Access Point.
WDS Station Mode Station mode expands the WDS by receiving a wireless signal/service and sharing it through the Ethernet port.
Chapter 5 Status 32
Main Status Save Changes Note: VLAN ID information is only applicable in Access Point or WDS AP mode. This page lets you save and apply the settings shown under Unsaved changes list, or cancel the unsaved changes and revert to the previous settings that were in effect. *The model name will be varied by different models. • *The model name will be varied by different models.
• The Statistics section shows Mac information such as SSID, MAC address, RX and TX. • The LAN Information section shows the Local Area Network settings such as the LAN IP Address, Subnet mask, and DNS Address. • The Wireless LAN Information 5 GHz section shows wireless information such as Operating Mode, Frequency, and Channel.
Connection Realtime 5 GHz Connection List The Realtime section contains the following options: Click the connection link under the Overview menu displays the connection list of clients associated to the AP/CPE’s 5 GHz, along with the MAC addresses and signal strength for each client. Clicking Refresh updates the client list. CPU Loading: 3 minutes CPU loading percentage information, it displays current loading, average loading and peak loading status.
Realtime Connection (Pkts): Overview on current active network connections. It displays UDP and TCP packets information and other connection status. UDP connections curve is in blue; TCP connection curve is in green; others curve is in red. Below of chart shows connections source and destination.
Chapter 6 Network 37
Basic IP Settings IPv4/IPv6 Settings Primary/Secondary DNS: The primary/secondary DNS address for this device. This page allows you to modify the device’s IP settings. Save: Click Save to confirm the changes. Spanning Tree Protocol (STP) Settings This page allows you to modify the Spanning Tree settings. Enabling the Spanning Tree protocol will prevent network loops in your LAN network.
Forward Delay: Specifies Bridge Forward Delay in seconds. Forwarding delay time is the time spent in each of the Listening and Learning states before the Forwarding state is entered. This delay is provided so that when a new bridge comes onto a busy network, it analyzes data traffic before participating in the network. Priority: Specifies the Priority Number. A smaller number has a greater priority than a larger number. Save: Click Save to confirm the changes.
Chapter 7 Wireless 40
Wireless Wireless Settings *The model name will be varied by different models. Device Name: Enter a name for the device. The name you type appears in SNMP management. This name is not the SSID and is not broadcast to other devices. Save: Click Save to confirm the changes. EnJet The AP/CPE is default EnJet enable. When enable the EnGenius EnJet system, the AP/CPE can then transmit data more efficiently, avoid collisions, and reduce latency and packet losses.
Channel: Click Configuration button to open a new windows to configure channels for performing wireless service. This page displays the current status of the Wireless settings of the AP/CPE. Wireless Network EnStation5-ACv2/EnStationACv2/ENS500-ACv2/ ENS500EXT-ACv2 Wireless: The AP/CPE supports 802.11ac/n mixed mode in 5 GHz. Transmit Power: Sets the power output of the wireless signal. Bit Rate: 5GHz is default 6 Mbps, the range can control by BAR via scroll from 6Mbps to 54Mbps.
use by scanning nearby areas for Access Points. Distance: Specifies the distance between Access Points and client devices. The proper setting for this parameter SSID Profile when EnJet disable may assist Access Points to avoid the improper operation when transmitting data under a filed application. AP Time Slot:In EnJet mode, the AP will assign time slots for each client’s data transmission. The larger the slot, the faster the data transmission.
Hidden SSID: Check this option to hide the SSID from clients. If checked, the SSID will not appear in the site survey. Client Isolation: Click the appropriate radio button to enable this function for allowing or preventing communication between client devices. VLAN Isolation: Restrict clients communicating with different VIDs by selecting the radio button. L2 Isolation: Enable this function prevenet client devices to communicate on the both WLAN and LAN. VLAN ID: Specifies the VLAN tag for each profile.
Wireless Security seconds, the Group Key changes. The default value is 3600 The Wireless Security section lets you configure the AP’s security modes Radius Server: Enter the IP address of the Radius server. Radius Port: Enter the port number used for connections to the Radius server. Radius Secret: Enter the secret required to connect to the Radius server. Secuirty Mode: Including WPA2-PSK, WPA2-Enterprise. We strongly recommend you to use WPA2-PSK mode.
Radius Settings Fast Roaming NAS-ID: Enable or disable accounting feature. Enable the function to serve mobile client devices that roam from Access Point to Access Point. Some applications running on Client devices require fast re-association when they roam to a different Access Point NAS-Port: Enable or disable accounting feature. NAS-IP: Enable or disable accounting feature. Radius Accounting Radius Accounting: Enable or disable accounting feature.
Wireless MAC Filtering Wireless MAC Filtering is used to allow or deny network access to wireless clients (computers, tablet PCs, NAS, smartphones, etc.) according to their MAC addresses. You can manually add a MAC address to restrict permission to access the AP/CPE. The default setting is: Disable Wireless MAC Filter. ACL Mode: Determines whether network access is granted or denied to clients whose MAC addresses appear in the MAC address table on this page.
Wireless Traffic Shaping Traffic shaping regulates the flow of packets leaving an interface to deliver improved Quality of Service. The function will allow administrators to restrict the wireless bandwidth per SSID. Enable Traffic Shaping: Check this option to enable Wireless Traffic Shaping. Download Limit: Specifies the wireless transmission bandwidth used for downloading. Upload Limit: Specifies the wireless transmission bandwidth used for uploading. Save: Click Save to confirm the changes.
Guest Network Settings the addresses by the DHCP server. Adding a guest network when EnJet disable allows visitors to use the Internet without giving out your office or company wireless security key. You can add a guest network to each wireless network in the 5 GHz ac/a/n frequencies. Ending IP Address: The last IP Address in the range of addresses assigned by the DHCP server.
Management VLAN Settings Management VLAN: If your network includes VLANs, you can enable Management VLAN ID for packets passing through the Access Point with a tag. This page allows you to assign a VLAN tag to packets sent over the network. A VLAN is a group of computers on a network whose software has been configured so that they behave as if they were on a separate Local Area Network Save: Click Save to confirm the changes or Cancel to cancel and return to previous settings. (LAN).
Chapter 8 Management 51
Advanced Settings SNMP Settings Location: Specifies the location of the device. This page allows you to assign the Contact Details, Location, Community Name, and Trap Settings for a Simple Network Management Protocol (SNMP). SNMP is a networking management protocol used to monitor network attached devices. SNMP allows messages (called protocol data units) to be sent to various parts of the network.
CLI Settings Email Alert You can use the Email Alert feature to send messages to the configured email address when particular system events occur. Note: Do NOT use your personal email address as it can unnecessarily expose your personal email login credentials. Use a separate email account made for this feature instead CLI: The Command Line Interface (CLI) allows you to type commands instead of choosing them from a menu or selecting an icon.
Username: Enter the username for the email account that will be used to send emails. Password: Enter the password for the email account that will be used to send emails. SMTP Server: Enter the IP address or hostname of the outgoing SMTP server. Port: Enter the SMTP port number to use for outbound emails. Security Mode: Selects the security mode: SSL/TLS or STARTTLS or None. Apply: To save setting and take effect.
Time Zone Time Setting Start: Select the day, month, and time when daylight savings time starts. This page allows you to set the internal clock of the EnStationAC. End: Select the day, month, and time when daylight savings times ends. Manually Set Date and Time: Manually specify the date and time. Automatically Get Date and Time: Select and check whether you wish to enter the IP address of an NTP server or use the default NTP server to have the internal clock set automatically.
Auto Reboot Settings You can specify how often you wish to reboot the EnStationAC. Auto Reboot Setting: Enables or disables the Auto Reboot function. Frequency of Auto Reboot: Specifies how often you wish to reboot the EnStationAC by Min, Hour, Day or Week. Timer: Select the day and enter the time you would like to reboot automatically. Save: Click Save to apply the changes.
Wi-Fi Scheduler drop-down list. The Wi-Fi Scheduler can be created for use in enforcing rules. For example, if you wish to restrict web access to Mon-Fri from 3pm to 8pm, you could create a schedule selecting Mon, Tue, Wed, Thu and Fri while entering a Start time of 3pm and End Time of 8pm to limit access to these times. Day(s): Place a checkmark in the boxes for the desired days or select the All Week radio button to select all seven days of the week. Duration: The Start Time is entered in two fields.
Tools Ping Test Parameters Target IP: Enter the IP address you would like to trace This page allows you to analyze the connection quality of the EnStationAC and trace the routing table to a target in the network. Nslookup Test Parameter Target IP/Domain Name:Enter the IP address or domain name you wish to do Nslookup test. Speed Test Parameters Target IP: Enter the IP address you would like to search. Ping Packet Size: Enter the packet size of each ping.
Device Discovery This page allows you to discover devices from network for Operation Mode, IP Address, System MAC Address and Firmware version.
Account Firmware This page allows you to change the EnStationAC username and password. By default, the username is: admin and the password is: admin. The password can contain from 0 to 12 alphanumeric characters and is case sensitive. Firmware Upgrade This page allows you to upgrade the firmware of the EnStationAC. Account Settings To Perform the Firmware Upgrade: 1. Click the Choose File button and navigate the OS file system to the location of the upgrade file.
Backup/Restore Backup/Restore Backup Setting: Click Export to save the current configured settings. This page allows you to save the current device configurations. When you save your configurations, you also can reload the saved configurations into the device through the Restore Saved Settings from a file section.
User Setting Back Up Setting as Default: Click Backup to backup the user settings you would like to the device’s memory for the default settings. The function allows you to backup the current device configurations into the EnStationAC as the default value. If extreme problems occur, or if you have set the EnStationAC incorrectly, you can push the Reset button to revert all the configurations of the EnStationAC to the user default.
Log System Log Remote Log The EnStationAC automatically logs (records) events of possible interest in its internal memory. To view the logged information, click the Log link under the System Manager menu. If there is not enough internal memory to log all events, older events are deleted from the log. When powered down or rebooted, the log will be cleared. This page allows you to setup the Remote Log functions for the AP/CPE. Syslog: Enables or disables the syslog function.
Logout Reset Click Logout in Management menu to logout. In some circumstances, it may be required to force the device to reboot. Click on Reset to reboot or to reset the AP/CPE. *The model name will be varied by different models. Once you click reset button, you will see the options for reboot or restore this AP. *The model name will be varied by different models. Please confirm again to logout the system or not. Reboot the device: Click it to reboot this device.
Appendix 65
Appendix A - FCC Interference Statement Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.
Appendix B - Professional Installation Instruction (FCC) Installation Personal This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting. Installation Location The product shall be installed at a location where the radiating antenna can be kept 20 cm from nearby person in normal operation condition to meet regulatory RF exposure requirement.
Appendix C - IC Interference Statement Industry Canada statement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device.
IMPORTANT NOTE: Radiation Exposure Statement Radiation Exposure Statement: This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Déclaration d’exposition aux radiations: Cet équipement est conforme aux limites d’exposition aux rayonnements ISED établies pour un environnement non contrôlé.
Appendix D Professional installation instruction (IC) 1. Installation personal This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting. 2. Installation location The product shall be installed at a location where the radiating antenna can be kept 20cm from nearby person in normal operation condition to meet regulatory RF exposure requirement. 3.
Instructions d’installation professionnelle 1. Installation Ce produit est destine a un usage specifique et doit etre installe par un personnel qualifie maitrisant les radiofrequences et les regles s’y rapportant. L’installation et les reglages ne doivent pas etre modifies par l’utilisateur final. 2.