PLEASENOTE:
Thefollowingadditionstoyourowner’smanualwillenableyoutoachieveoptimal
emissionsperformancefromyourstove.
ProperInstallationPleaserefertotheInstallationsectionofyourowner’smanualandfollow
theguidelineslistedthereinforsafetyandforoptimalemissionsperformance.
Additionalinformation:
VentingIntroduction:
Draft:Draftistheforcewhichmovesairfromtheapplianceupthroughthechimney.Theamount
of draft in your chimney depends on the length of the chimney, local geography, nearby
obstructions and other factors. Too much draft may cause excessive temperatures in the
applianceandmaydamagethecatalyticcombustor.Inadequatedraftmaycausebackpuffinginto
theroomand‘plugging’ofthechimneyorthecatalyst.
Inadequate draft will cause the appliance to leak smoke into the room through appliance and
chimneyconnectorjoints.
Anuncontrollableburnorexcessivetemperatureindicatesexcessivedraft.
Pleasebemindfulofinstallationlocation:Inversionandotherairqualityissuescanariseinvalleys
orifunitisinstalledclosetoneighboring
homes.
Thiswoodstoveoperatesonanaturaldraftsystem,inwhichthechimneysystempullsair
throughthestove. Thisunitmustbeinstalledinaccordancewiththefollowingde tailed descriptions
ofventingtechniques;notinstallingthestoveinaccordancewiththedetailslistedherecanresultin
poorstoveperformance,
propertydamage,bodilyinjury ordeath. Avoidmakeshiftcompromises
wheninstallingtheventingsystem. England’sStoveWorksisnotresponsibleforanydamageincurred
duetoapoororunsafeinstallation.
Becertainthatallaspectsoftheventingsystemareinstalledtotheventingmanufacturer’s
instructions,particularlythe
requiredclearancestocombustibles. Also,becertaintouseanattic
radiationshieldtopreventinsulationfromcontactingachimneywhichpassesthroughanattic.
Thechimneysystemisthe“engine”whichdrivesawoodstove,soitisimperativeforproper
unitfunctionthattheventingsystembeinstalledexactlyasdescribedinthefollowingsection.
Ifquestionsarisepertainingtothesafeinstallationofthestove,ourTechnicalSupportline
(8002456489)isavailable.Contactyourlocalcodeofficialtobecertainyourinstallationmeetslocal
andnationalfirecodes,andifyou’reuncertainabouthowtosafelyinstallthestove,westrongly
recommendcontactingalocalNFIcertifiedinstallertoperformtheinstallation.
WOOD - Meetsthe2015U.S.EnvironmentalProtectionAgency’scribwood
emissionlimitsforwoodheaterssoldafterMa
y
15
,
2015