Use and Care Manual

2.0ft.
3.0ft.
INSTALLATION
Approved Venting Method 2:ThroughtheCeiling
10
ft.
TerminationCap
StormCollar
The 1032 Rule:Thechimneysystem
mustterminate3.0ft.abovethepoint
whereitscenterlinepassesthroughthe
roofANDthechimneymustterminate
2.0ft.aboveanypartofthedwelling
withina10ft.radiusofthechimney.
RoofFlashing
ClassAChimneySystem
CeilingSupportBox
ChimneyConnector
(SingleorDoubleWall)
PrefabricatedchimneysystemsmustconformtoUL103HT(2100°F)fortheU.S.andULCS629(650°C)for
Canada.
Thiswoodburningunitisonlylistedforinstallationwith6.0”diameterchimneyconnectorandchimneysystems.
Installingthisunitonprefabricatedchimneyslargerthan6.0”diameterwillresultindecreaseddraftandthepotential
forpoorunitperformance.
Followallventingsystemmanufacturer’sinstallationrequirementsandrequiredclearances.
Usethreesheetmetalscrewsateachsinglewallchimneyconnectorjoint(checkmanufacturer’s
recommendationswhendoublewallchimneyconnectorisused).
Drillthreeholesinthefluecollaroftheunitandattachthechimneyconnectortotheunitusingsheetmetalscrews
(holesshouldbepredrilledinfluecollarfromfactory).
Properlyattachtheprefabricatedchimneysystemtothehomeinstrictaccordancewiththeprefabricatedchimney
systemmanufacturer’sinstructions.
Theoveralllengthofthechimneyconnectormustnotexceed8.0ft. Inthecaseofcathedralceilings,the
prefabricatedchimneysystemshouldextendto8.0ft.fromthetopoftheunitifusingsinglewallchimney
connectorpipe.Ifnecessarytorunlongerthan8.0ft.ofchimneyconnectorpipe,do
ublewallblackchimney
connectorpipemustbeused.
Specialadaptersandslipconnectorsareavailabletoeliminatetheneedtocutsinglewallchimneyconnector.
Doublewallchimneyconnectormustbeusedwiththeseslipconnectors,asitcannotbetrimmedtolength.
Please Note:Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplans
foreachindividualinstallation. Pleasefollowallventingsystemrequirements,maintaintherequiredclearancesto
combustibles,andfollowalllocalcodes
13