Use and Care Manual

15
COMPONENTREPLACEMENT
(WARNING:Aswithanymaintenanceconcerningthisunit,besuretheunitis“OFF”andhas
completedtheShutDowncycleBEFOREbeginning.Unplugtheunit.Beawarethatmetal
partscanremainHOTlongafterthefirehasgoneoutandEVENaftertheShutDowncycleis
complete.Always
useextremecautionwhenhandlingpotentiallyhotparts,evenifyouthink
theyshouldbecold.)
Coverpanel
Toremovethecoverpanel:Usinga5/16”socket,loosenandremovethesixscrewsonthe
coverpanel,thenslidethepaneloutandsetaside.Whenfinishedwithanytroubleshootingor
componentreplacement,reinstallthepanelinthereverseofthismethod.
Refertothisillustrationfortheproceduresonthispage
Combustionfan
Removethecoverpanel.Unplugthewiresfromthefan.Liftthefanupandthenremove.
*Becausethegroundwireisattachedtotheunitonthecombustionchamber,itmaybe
necessarytoloosenthisscrewtoremovethecombustionfan.Toinstallthenewfan,usethe
reverse
ofthismethod,beingsuretoinstallthefaninthecorrectdirection(withthefan
blowingintothechamber).
Hopperlidsafetyswitch
Loosenthe½”nut,andthenremovethenutandwasher.Unplugthewiresfromtheswitch,
takingnoteofwherethewiresareconnected.Toinstallthenewswitch,connectthewiresto
thenewswitchandthenplacetheswitchbuttonintotheholeandinstallthenut
andwasher,
beingcarefulnottoovertighten.
Augermotor/Auger
*Besuretoremoveallthepelletsfromthehopperbeforetryingtoremovetheaugerorauger
motor.*Removethecoverpanel.Unplugtheaugermotorwiresfromthewiringharness.
(Continuednextpage.)