Installation Guide
34
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
REPLACINGCOMPONENTS
AugerMotor
1. Beforebeginninganycomponentreplacement,becertaintheunitisunpluggedandthoroughly
cooleddown.Also,makesurethehopperisemptybeforeattemptingtoremoveorreplacethe
augermotorassembly.
2. Removethebackpaneloftheunit,usinga
5
/
16
”wrench.Beforelooseninganyaugermotor
bolts,detachthewiringharnessfromtheaugermotor.
3. Locatetheaugermotorassemblyattherearofthestove,andbeginbylooseningthetwo
1
/
8
”
allensetscrewsoneithersideofthecastironaugermotorcoupler.
4. Slidetheaugerassemblyoutofthetube.
5. Next,removethefourscrewswhichholdthecastironaugermotorcouplertotheaugermotor,
usinga
5
/
16
”wrench.Slidethecastironaugermotorcouplerandthesteelspacerplateoffof
theaugermotor.
6. Loosenthe
1
/
8
”allensetscrewwhichholdsthesteelaugercouplertotheaugermotoroutput
shaft,andremovethesteelaugercoupler,aswellastherubbervibrationdampener.
7. Reinstallthepartsinreverseorderonthenewaugermotor,beingcarefulnottoover‐tighten
theboltswhichholdthecastironaugercouplertotheaugermotor.