IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING
THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT,
OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY
QUESTIONS.
INSTALLATION
ApprovedVentingMethod3:ExistingChimneySystem
x Usinganexistingmasonryorfactorybuiltchimneyforventingistheonlyotheracceptablemethod
forventingthispelletunit.
x UseTypeLorTypePLventingpipeuntilenteringtheexisting
chimney.Usetheappropriatelysizedadapterwhen
transitioningfromthepelletventpipetothemasonryorfactory
builtthimbleandbecertainthattheadapterissealedtightlyto
boththepelletventingsystemandtheexistingchimney.
x Beforeusinganexistingchimney,becertainitisingood
condition(Achimneysweepinspectionishighlyrecommended).
Also,makesurethechimneymeetstheminimumstandards
listedinNFPA211(Achimneyprofessionalcanconfirmthisupon
inspection).
x Ifconnectingthisstovetoafactorybuiltchimney,itmay
ONLYbea6”flue,UL103HTventingsystem(ULCS629if
Canada).Connectiontoanyotherfactorybuiltchimneymay
resultinapoorlyoperatingordangerousstoveinstallation.
x Whenconnectingtoanexistingmasonrychimney,thecrosssectionalareaofthefluemustbe
considered.Achimneywithafluelargerthan6”round(28.27sq.in.)mayrequirereliningwithan
approvedpelletstovechimneyliningsystem.
x Useanappliancecollarwherethepelletventconnectstotheexhaustoutputofthepelletstove
andattachtheappliancecollartotheexhaustbloweroutputusingthreesheetmetalscrews.
x SealeachpipeconnectionjointwithhightemperatureRTVSilicone,toensurethesystemisleak
free(Checkwiththespecificpipemanufacturer’sinstructionsbeforedoingso).
x Ifthepelletventpipebeingusedisnota“TwistLock”system,three(3)sheetmetalscrewsare
requiredateachpipejoint.
x Connectthepelletstovetooutsidecombustionairusingthekitincludedwithyourstoveorusing
analternativemethod,asdescribedinthe“OutsideAir”section,onpage15.
PleaseNote:
Installationdiagramsareforreferencepurposesonlyandarenotdrawntoscale,normeanttobeusedasplansforeach
individualinstallation.Pleasefollowallventingsystemrequirements,maintaintherequiredclearancestocombustibles,
andfollowalllocalcodes.
Forhighaltitudeinstallations
(above4,000ft.),theventpipe
shouldbeincreasedfrom3inch
(
3”
)
tofourinch
(
4”
)
.