Use and Care Manual

13
SECTION VIII: CARE AND MAINTENANCE
(Unit must be cool and power unplugged
before performing any maintenance)
A. Gaskets
Each unit comes with a rope gasket around the door, which should be
replaced at least every two years. To replace the gasket, the old gasket
material should be removed and the door channel scraped free of any
adhesive. You can then add the new adhesive and the gasket
(Part AC-DGKC) and close the door. The door should be closed for at
least twenty-four hours to allow the adhesive to harden.
B. Firebrick
This furnace is equipped with high density, high temperature firebrick. Any
brick that become chipped or cracked, especially on the sides of the
firebox, need to be replaced.
C. Finish
This unit is coated with high-temperature paint that will retain its original
look for several years. If the unit should get wet, rust spots may appear;
these can easily be covered with this high-temperature spray paint (plain
steel wool can be used to remove the rust spots before repainting). Please
contact your dealer or the factory for this paint, as other brands may not
adhere to the surface of this furnace.
D. Blower and Thermostat
This furnace comes with a 850 CFM blower (Part BM-1376). Over a
period of time the intake of the blower can become clogged with lint or
dust, and it will require some cleaning. To do this, unplug the blower from
the power source and remove the screws that hold the blower to the stove
(be sure the stove is cool before doing so). Then unscrew the motor from
the blower and remove it, along with the impeller. A vacuum cleaner can
be used to remove the foreign material from the intake. Reverse this
procedure to re-mount the blower to the furnace.
The AC-1339 thermostat requires no maintenance. It activates the blower
when the firebox temperature rises to 125 degrees Fahrenheit; it also
deactivates the blower when the temperature drops to 95 degrees
Fahrenheit. By shutting off at 95 degrees, it allows the furnace to recover
as the heat is extracted from the unit and forced through the duct system.
We recommend that you leave the thermostat at the factory settings
until the unit has been burned for at least 30 days.
Refer to the list at the rear of this
manual for part numbers.
You may order parts by calling
(800) 516-3636 or logging on to
www.englanderstoves.com .