Installation Diagrams and Thermostat Wiring 
Figure 2 – Installation into a HT Pipe Flue System. 
LEFT
 – Through the Roof RIGHT – Through the Wall 
Figure 1 – Installation into a Masonry Flue 
Figure 3 – Hot air outlet hook-up to ductwork. 
NOTE: Be sure to connect to ductwork from 
furnace’s 8” hot air outlet only (see Section V)
. 
A
ir Flow 
Figure 4 – Blower thermostat wiring diagram. 
IMPORTANT NOTE: Do NOT connect this furnace to 
an external thermostat. 
18” Min. 
18” Min.
NOTE: 13” required from back of unit to a combustible. 
16” required from sides of unit to a combustible. 
See Floor and Wall Protection sections and data label 
on stove for all clearances. 
18” Min.
Recommended position 
of Backflow Damper 
To prevent air flow from central furnace 
being directed back into the Add-on furnace: 
A Backflow Damper is required in the 8” hot air 
outlet pipe that connects from the Add-On 
Furnace to the Central Furnace (see Figure 3). 
We also recommend a 8” (eight inch), 90 
degree elbow (a slightly larger hole will be 
required for installation) inside central furnace 
p
lenum or ductwork.  