Installation Guide

8
INSTALLATION APPLICATIONS
Illustration 1
16.0” Min.
16.0” Min.
16” Min.
18.0” Min.
18.0” Min.
NOTE:
1.
Horizontal run not to exceed 6’.
2. Total flue length should not
exceed 25’.
3. Floor protection required:
Min. size 39” x 52.5”.
4. Always check local codes for
clearances, installation, etc.
See
N
ote
(
3
)
See Note
(
3
)
See Note (3)
See Note (3)
And Floor Protection section
B
D
Masonr
y
Chimne
y
(Exterior) Wall
Supported
(Interior) Ceiling
Supported
Single Wall
Chimney
Connector
Lined with
clay tile or
other liner
C
E
A
*IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by
the malfunction of a stove due to improper installation. Do not use makeshift methods or material
which may compromise the installation. England’s will not be liable for consequential or indirect
damages to property or persons resulting from the use of this product.
Call
(
800-245-6489
)
and/or consult a
p
rofessional installer if
y
ou have an
y
q
uestions.
Single Wall
Chimney
Connector
Class “A”
Chimney System
Followallventingsystemmanufacturer’s
installationrequirementsANDtheir
requiredclearances.