INSTALLATION & OPERATION MANUAL Pellet Stove MODELS 25-PDVC / 25-PDVCH / 55-SHP10/ 55-SHP10L / 55-TRP10 Manufactured By: England’s Stove Works, Inc. PO Box 206 Monroe, VA 24574 Rev. 1/2022 www.heatredefined.
Welcome! Introduction Auger Motors ........................................ 18 Precautionary Statements ........................ 3 Auger Bearings & Shafts ....................... 18 Unit Specifications ………………………4 Convection Blower ................................ 18 Thank You .............................................. 5 Combustion Blower ............................... 18 Read Before Getting Started .................... 6 Vacuum Switch ................................
INSTALLATION & OPERATION MANUAL MODEL NUMBERS: 25-PDVC, 25-PDVCH, 55-SHP10, 55-SHP10L, 55-TRP10 Thank you for purchasing this product from a fine line of heating equipment. We wish you many years of safe heating pleasure with your new heating appliance. Save These Instructions. IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO THE DEALER. CONTACT TECHNICAL SUPPORT @ 1-800-245-6489.
SPECIFICATIONS Heating Specifications Approximate Pellet Burn Rate**……1.0 to 1.8 kg/hr (2.2 to 3.8 lbs/hr) Maximum Burn Time**………………………………………………..20 hours Approximate Square Footage Heated***………………….up 2,000 sq. ft. Hopper Capacity (fuel)………………………………………….…..40 pounds EPA and Safety Compliance Specifications EPA Compliance Status …………………. Certified to comply with 2020 particulate emission standards using pellet fuel. U.S. Test Standard: US EPA 40 CFR Part 60, Subpart 60.
Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works was started, and is still owned by, a family that believes strongly in a "Do It Yourself" spirit – that’s one reason you found this product at your favorite “Do It Yourself” store. We intentionally design and build our stoves so that any homeowner can maintain his or her unit with basic tools, and we're always more than happy to show you how to do the job as easily and as inexpensively as possible.
BEFORE RE-STARTING YOUR UNIT Every time before pressing “ON” to start your unit – Be sure to remove all ashes (burnt or partially burnt) from your burn pot area! Wearing protective gloves and with the unit cool, remove the Wear Plate and dump the ashes, ensuring that the air holes are clear from debris. Also be sure to follow all other maintenance instructions as outlined in your Owner’s Manual and youtube.com/heatredefined.
IMPORTANT INFORMATION 1. Check local installation codes for your area. Call your Homeowner’s Insurance representative for inspection of your stove’s installation. 2. Read and comply with the instructions in this manual. 3. This unit should be tested (dry run) before loading pellets for 20 minutes. The stove should automatically shut itself off after the 20-minute dry run. SEE the ‘Operating Instructions’ section. 4. Your stove is designed to burn Wood Pellets only.
14. Do not allow paint, chemicals or construction dust on or near your unit. Do not allow liquid or ANY foreign materials on or inside your unit. Shut your unit down and cover it when painting, construction or similar activity is taking place. Wipe and clean your unit after any construction is done in your home, or if any foreign material gets on or inside your unit.
IMPORTANT NOTICE: This unit must be properly installed to prevent the possibility of a house fire or “smoke-back.” The instructions must be strictly adhered to. Do not use makeshift methods or material which may compromise the installation. Your unit requires periodic maintenance and cleaning (refer to manual). Failure to maintain your unit may lead to a variety of problems, including but not limited to smoke spillage into the home.
The through-the-wall installation is the least expensive and simplest installation. In a through-the-wall installation you should be mindful of the snowdrift line, as well as dead grass and leaves. We recommend a three foot (3’) minimum vertical rise on the inside or the outside of the dwelling.
Freestanding Pellet Installation Caution: Follow the pipe manufacturer’s installation instructions and directions for passing through combustible walls and ceilings. Check local codes in your area. Illustration 1 Must have minimum 3” adapter before tee for longer run. For shorter run (such as Masonry Connection below), tee alone is acceptable. Our Part AC-3000 is acceptable for through-the-wall installation; AC-3100 for 4000+ ft. installations.
VENT TERMINATION CLEARANCES A) MIN. 4-FT CLEARANCE BELOW OR BESIDE ANY DOOR OR WINDOW THAT OPENS. B) MIN. 1-FT CLEARANCE ABOVE ANY DOOR OR WINDOW THAT OPENS. C) MIN. 2-FT CLEARANCE FROM ANY ADJACENT BUILDING. D) MIN. 7-FT CLEARANCE FROM ANY GRADE WHEN ADJACENT TO PUBLIC WALKWAYS. E) MIN. 2-FT CLEARANCE ABOVE ANY GRASS, PLANTS, OR OTHER COMBUSTIBLE MATERIALS. F) MIN. 3-FT CLEARANCE FROM A FORCED AIR INTAKE OF ANY APPLIANCE. G) MIN. 2-FT CLEARANCE BELOW EAVES OR OVERHANG. H) MIN.
OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE WITH THE DOOR OPEN. If door is left open (approximately) two minutes, unit will stop feeding and fire will go out. This stove has an induced draft system and is designed to operate continuously, as frequent shutdown is not required. The digital control board operates the unit with a time delay-relay system; this system controls the top auger feed rate by operating for a predetermined number of seconds while the bottom auger runs constantly.
lantern fuel, kerosene, charcoal lighter fluid, diesel fuel or any other flammable liquid to start the fire. Do not use the manual startup method if the igniter is working. NEVER place firestarter near the igniter. If you have continued problems with the Auto-Start Igniter, call Technical Support. E-Codes “E-Codes,” or Error Codes, are codes that will appear in the Heat Range and Blower Speed windows of the Control Board if your unit experiences problems.
DAILY OPERATION Refueling the Unit Always press the “OFF” touch pad before refueling. This unit has a 40-lb. hopper, and should be refilled when the hopper level drops to three or four inches. Do not install or operate this unit outside, in a greenhouse, or in any area that is high in moisture. Note: The hopper lid will be warm; therefore, you should always use some type of hand protection. NEVER place your hand near the auger while the stove is operating.
As with any maintenance concerning this unit, be sure the unit is “OFF” and has completed the ShutDown cycle BEFORE beginning. Be aware that metal parts in the firebox can remain HOT long after the fire has gone out and EVEN after the Shut-Down cycle is complete. Always use extreme caution when handling potentially hot stove parts, even if you think they should be cold.
Monthly Ash Removal The large baffle plate (12” x 13”) that rests above and behind the burn pot (refer to the exploded diagram in the rear of this manual – Illustration 6) should be removed monthly. This can be done by lifting up the plate and pulling it out. The area behind the plate should then be cleaned thoroughly, and the plate placed back in the original position.
MAINTENANCE CAUTION: UNPLUG THE UNIT PRIOR TO ANY SERVICE WORK! SEE EXPLODED DIAGRAM (ILLUSTRATION 6) FOR PARTS REFERENCE Parts Orders: (800) 516-3636 www.HeatRedefined.com Questions: (800) 245-6489 NOTE: The maintenance procedures described in this manual (including cleaning and parts and gasket inspection and replacement) can be found at youtube.com/heatredefined. Click on Playlists to find your stove’s model number to see detailed ‘How To’ videos.
Vacuum Switch This unit is equipped with a Vacuum Shut Down Switch (Part CU-VS), which help control various functions of the unit. If an operational error occurs in the unit, a switch will either stop the top (feed) auger or shut the unit off; if the unit turns off an E-1 Code (error code) will appear in the Heat Range and Blower Speed windows of the Control Board.
Hopper Lid Safety Switch This unit is equipped with a hopper lid safety switch (Part # AC-HLSB) which is directly connected to the top auger motor. In the event the hopper lid is left open while the stove is in operation, the hopper lid switch will prevent the top auger from turning. This is to prevent byproducts of combustion from entering the home through the open hopper lid and also to simply prevent operation with the hopper lid open.
Control Board The Control Board (Part # PU-CB19) is a digital read-out board. This board offers a wide variety of settings to operate the unit. This part can be removed from the unit by loosening the two outside screws and pulling the board back to the inside of the stove. The rear access panel should be removed prior to removing the control board. A 6-amp “quick-blow” fuse (Part # PU-CBF6) is used on this Control Board.
Illustration 4 PU-CB19 Control Board Wiring Diagram CAUTION: Moving Parts May Cause Injury. Do NOT Operate with Panel(s) Off. DANGER: Parts May Be Hot. Risk of Electric Shock. Disconnect Power Before Servicing Unit. IMPORTANT SAFETY NOTE: If the unit or chimney connector pipe “glows” red (or white), the stove is over-fired. This condition could cause a house or chimney fire. Do not operate your unit too hot, or over-firing may result.
Adjusting Hopper Lid Latches The seals around the top of the pellet hopper are important to safe and efficient operation of the unit. The latches installed on these units are designed to pull the hopper lid tight against this seal. Over the course of operation as these seals “wear in” and compress, the tension of the latches should be tested periodically, and adjusted if necessary. To adjust the lid latches, the following tools will be needed; two ½ inch wrenches, or a ½ inch wrench and a ½ inch socket.
ACCESSORY ITEMS The following accessories can be added to your unit at anytime after purchase; however, let the unit cool down before adding any accessories. Thermostat An external wall thermostat can be used on our pellet units, as long as it is a low-voltage type that works with millivolt systems. After unplugging the unit, locate the jumper wire (J-18) on the bottom of the control panel. The two screws should then be loosened and the jumper wire removed from the board.
REPLACEMENT PARTS, ACCESSORIES AND OPTIONS AC-HP AC-CT Glass Gasket Kit (gasket only, no glass) Door Gasket Kit (#2 on diagram) 9” x 9” Glass with Gasket (#3 on diagram) Nickel Door Spring Handle Hi-Temperature Black Paint 1 RPM Auger Motor Assembly (#18 on diagram) Burn Pot Wear Plate (fits inside Burn Pot) Combustion (Exhaust) Blower (includes 3” adapter) (#’s 8 and 9 on diagram) Convection (Room Air) Blower (#13 on diagram) Top Auger Shaft (#14 on diagram) Bottom Auger Shaft (#14 on diagram) Hopper Lid
Pellet Stove – Exploded View Diagram Illustration 6 Unit Dimensions: 24" W x 28 1/2" H x 28" D Unit Weight: 285 lbs. (Approx. 13 ½” height from floor to center of exhaust) IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT.
TROUBLE-SHOOTING GUIDE WARNING: TO AVOID ELECTRICAL SHOCK ALWAYS DISCONNECT THE UNIT FROM THE POWER SOURCE BEFORE ATTEMPTING ANY REPAIR. IF THIS GUIDE DOES NOT CORRECT THE PROBLEM CALL YOUR LOCAL DEALER OR OUR TECHNICAL SUPPORT AT 1-800-245-6489. Problem Cause Loose set screw Bad gear motor Foreign matter in auger Vacuum sensor (Top Auger) Carbon buildup in feed auger tube Solution 1. Auger not turning 1. 2. 3. 4. 5. 2. Smoke smell or dust in house 1. Improper exhaust connection 1.
You may write your unit’s Manufacture Date and Serial Number in the blank spaces on this sample tag, for future reference. This sample tag also shows the safety info. such as UL/ULC testing standard, etc. for your local officials, or anyone else who may need reference IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.
Have this information on hand if you phone the factory or your dealer regarding this product. Retain for your files: Model Number __________________________ Date of Purchase ________________________ Date of Manufacture _________________ Serial #_____________________ LIMITED 5 YEAR WARRANTY FROM THE DATE OF PURCHASE TO THE ORIGINAL OWNER The manufacturer extends the following warranties: Five Year Period: 1. Carbon steel and welded seams in the firebox are covered for 5 years against splitting. 2.
Important Notice This registration information MUST be on file for this warranty to be valid. Please mail this information within thirty (30) days from the original date of purchase. Use any of these three easy ways to send your warranty information in! Mailing Address England’s Stove Works, Inc. Technical Support Department P.O. Box 206 Monroe, Virginia 24574 Fax Number (434) 929-4810 – Twenty-four hours a day. Online Registration Visit our warranty registration website at: http://www.heatredefined.
WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) ______________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ Telephone _______________________________________________________ Email Address ___________________________________________________ DEALER INFORMATION Purchased From (Dealer) ___________________________________________ Address _________________________________
IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED. ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH ANY QUESTIONS.
PELLET - Meets the 2015 U.S. Environmental Protection Agency’s PLEASE NOTE: wood emission limits for wood heaters sold after May 15, 2015 EPA INFORMATION The following additions to your owner’s manual will enable you to achieve optimal emissions performance from your stove. Important safety tips are also included. ‐ Proper Installation – Please refer to the Installation section of your owner’s manual and follow the guidelines listed therein for safety and for optimal emissions performance.
Additional Venting Information Do not mix and match components from different pipe manufacturers when assembling your venting system (i.e. Do NOT use venting pipe from one manufacturer and a thimble from another). We require a minimum vertical rise of 36 in. (3 ft.) of pipe to create natural draft in the system, which helps evacuate smoke from the stove in the event of a power failure or combustion blower failure. Venting systems 15.0 ft. or shorter may be composed entirely of 3.0 in.
OUTSIDE AIR HOOK‐UP The use of outside combustion air is mandatory on this pellet stove. The outside air connection pipe protrudes from the lower rear center of the stove; use the included outside air kit to attach your stove to outside combustion air. Instructions and all the parts needed to make the outside air connection to your pellet stove are included with the outside air kit.
Daily Operation Notes Only high quality, ¼” (.25 in.) diameter wood pellets, should be used in this stove. Using low grade wood pellets with high ash content OR wood pellets with a high moisture content can cause the burn pot to fill with ash at a more rapid pace and can cause intervals between periodic maintenance to become significantly shorter. Please read the “Maintenance” section of this manual thoroughly to understand how fuel selection affects stove operation, maintenance and cleaning.
Air Controls: Your pellet stove is equipped with a control board that automatically adjusts the air to fuel ratio for optimum emissions. See your owner’s manual for information on operating the control board, and for other operational information on achieving the best burn, including these tips: The control board on this stove allows the user to adjust the heat output and convection blower speed, and turn the unit on and off.
‐ ASH REMOVAL – Follow your Owner’s manual’s instructions regarding removal and disposal of ashes. Also be sure to follow ALL Maintenance requirements as listed. ‐ REPLACEMENT of parts that are critical to emissions performance – Follow your Owner’s manual’s instructions regarding replacement of gaskets and other parts that are critical to emissions performance. Remember: “This wood heater needs periodic inspection and repair for proper operation.
Fabriqué par : England’s Stove Works, Inc. PO Box 206 Monroe, VA 24574, États-Unis GUIDE D’INSTALLATION ET D’UTILISATION 25-PDVC 25-PDVCH 55-SHP10 55-SHP10L 55-TRP10 1/2022 Questions? Besoin de pièces ou d'options? www.heatredefined.com Pour un service en Français – Courriel : infoenfrancais@englanderstoves.com Telephone (844) 411-2654 MISE EN GARDE VEUILLEZ LIRE L’INTÉGRALITÉ DU PRÉSENT GUIDE AVANT D’INSTALLER ET D’UTILISER CE POÊLE À GRANULES.
BIENVENUE! Introduction Illustration détaillée des pièces Merci ………...........................................4 Caractéristiques de chauffage ………….5 AVANT DE REDÉMARRER VOTRE APPAREIL...............................................6 INFORMATION IMPORTANTE .........7 PRÉPARATION DE L'APPAREIL .......8 Installation SYSTÈME DE CONDUIT DE FUMÉE .........9 INSTALLATION, CONT ...........................10 DÉGAGEMENTS DES TERMINAISONS DES ÉVENTS ...........................................
MANUEL D'INSTALLATION ET D'UTILISATION NUMÉROS DE MODÈLE 25-PDVC, 25-PDVCH, 55-SHP10, 55-SHP10L, 55-TRP10 Nous vous remercions d'avoir acheté ce produit d'une excellente gamme, de matériel thermique. Nous vous souhaitons de nombreuses années de plaisir au chaud et sans danger avec votre nouvel appareil de chauffage Conserver ces directives. IMPORTANT : SI VOUS AVEZ DES PROBLÈMES AVEC CET APPAREIL, NE PAS LE RETOURNER AU VENDEUR. COMMUNIQUER AVEC LE SUPPORT TECHNIQUE AU 1-800-245-6489.
CARACTÉRISTIQUES Caractéristiques de chauffage Taux approximatif de combustion des granules** ……. de 0,99 à 1,72 kg/h (de 2,2 à 3,8 lb/h) Durée maximale de combustion**…………………………… 20 heures Superficie approximative chauffée***…………………….. jusqu’à 185,8 m² Capacité de la trémie (granules)…………………………………………. 36,28 kg Conformité aux normes de sécurité et à celles de l’EPA État de conformité aux normes de l’EPA ………………….
Merci d’avoir acheté cet excellent produit de la gamme England’s Stove Works. La famille qui a fondé et possède encore England’s Stove Works croit fermement que les travaux que l’on réalise soi-même sont les plus satisfaisants; voilà pourquoi vous avez trouvé ce poêle auprès de votre magasin préféré de produits prêts à assembler. Nous concevons et fabriquons nos poêles expressément pour que n’importe quel propriétaire soit en mesure de les entretenir avec des outils de base.
AVANT DE REDÉMARRER VOTRE APPAREIL Chaque fois, avant d'appuyer sur « ON » pour démarrer votre appareil – Veiller à retirer toutes les cendres (brûlées ou partiellement brûlées) de l'aire de la chambre de combustion! En portant des gants de protection et l'appareil étant froid, retirer la plaque d'usure et jeter les cendres, en vérifiant que les trous d'aération sont exempts de débris.
INFORMATION IMPORTANTE 1. Vérifier les codes locaux d'installation de votre région. Appeler le représentant de votre assurance de propriétaire occupant pour une inspection de l'installation de votre poêle. 2. Lire et suivre les de ce mode d’emploi. 3. Cet appareil doit être testé (marche à vide) pendant 20 minutes avant de le charger en granules. Le poêle doit s'arrêter automatiquement après une marche à vide de 20 minutes. Voir la section Directives d'utilisation. 4.
14. Ne pas laisser de peinture, de produits chimiques ou de poussière de construction près de votre 15. 16. 17. 18. appareil. Ne pas laisser de liquide ni QUELCONQUES matières étrangères sur ou dans l'appareil. Fermer et couvrir l'appareil lors d'activités de peinture, de construction ou autres du même ordre. Essuyer et nettoyer votre appareil après toute construction faite dans la maison ou si des matières étrangères sont déposées sur ou dans votre appareil.
AVIS IMPORTANT : Il faut installer correctement cet appareil pour prévenir la possibilité d'un incendie ou d'un « retour de fumée ». Il faut suivre strictement les directives. Ne pas utiliser de méthodes ou de matériel improvisés qui pourraient compromettre l'installation. Votre appareil requiert un entretien et un nettoyage périodique (Consulter le mode d'emploi).
sous-sol, il faut utiliser un tuyau de 3 po (75 mm)et un raccord pour l'air comburant extérieur et il faut conserver un espacement minimal de 900 mm (3 pi) depuis le sol jusqu'au tuyau évacuation du conduit hors de l'habitation. L'installation à travers le mur est la moins chère et la plus simple. Dans une installation à travers le mur, vous devez tenir compte du niveau d'accumulation de la neige ainsi que de l'herbe et des feuilles mortes.
Installation d'un poêle à granules autonome Attention : Suivre les directives du fabricant du tuyau et les instructions pour le passer au travers de murs et de plafonds combustibles. Vérifier les codes locaux de votre quartier. Illustration 1 Notre pièce AC3000 est acceptable pour une installation à travers le mur. (AC-3100 pour des installations à 1200 m (4000 pi) et plus) AC-33000 ou AC33100 si le Canada Doit avoir un adaptateur d'au moins 3 po (75 mm) avant le té pour une portée plus longue.
DÉGAGEMENTS DES TERMINAISONS DES ÉVENTS A) DEGAGEMENT D’AU MOINS 1,22 M EN DESSOUS OU SUR LE COTE DE TOUTE PORTE OU FENETRE POUVANT S’OUVRIR. B) DEGAGEMENT D’AU MOINS 0,3 M AU-DESSUS DE TOUTE PORTE OU FENETRE POUVANT S’OUVRIR. C) DEGAGEMENT D’AU MOINS 0,61 M DE TOUT BATIMENT VOISIN. D) DEGAGEMENT D’AU MOINS 2,13 M A PARTIR DU NIVEAU DU SOL LORSQUE L’INSTALLATION JOUXTE LA VOIE PUBLIQUE. E) DEGAGEMENT D’AU MOINS 0,61 M AU-DESSUS DES HERBES, DES PLANTES ET DE TOUT AUTRE MATERIAU COMBUSTIBLE.
DIRECTIVES D'UTILISATION ATTENTION : NE PAS UTILISER AVEC LA PORTE OUVERTE. Si la porte est laissée ouverte pendant deux minutes (environ), l'appareil cessera d'être alimenté et le feu s'éteindra. Ne pas brûler de rebuts (sacs de papier, etc.) dans cet appareil.
E-Codes Les « E-Codes », ou codes d'erreur, sont des codes qui apparaissent dans les fenêtres du degré de chaleur et de la vitesse du ventilateur du tableau de commande si votre appareil présente des problèmes. Si un de ces codes est affiché, essayer d'abord de réinitialiser l'appareil en appuyant sur le bouton « ON » (une fois seulement). Si l'appareil continue d'afficher des E-Code(s), veuillez communiquer avec le support technique au (800) 245-6489 avant d'essayer de le redémarrer. 1.
UTILISATION QUOTIDIENNE Réalimentation en combustible Toujours appuyer sur la touche « OFF » avant de remettre du combustible. Cet appareil dispose d'une trémie de 18 kg (40 lb) qui doit être remplie lorsque son niveau baise à 75 ou 100 mm (3 ou 4 po). Note : Le couvercle de la trémie sera chaud; vous devez donc toujours protéger vos mains.
NOTE : Les directives ci-dessous relatives au nettoyage de l'aire de la chambre de combustion et de la plaque d'usure sont particulièrement importantes pour les fonctions de votre poêle.
Nettoyage mensuel des cendres Il faut retirer chaque mois le grand déflecteur (305 mm x 330 mm [12 po x 13 po]) qui est suspendu au dessus et derrière la chambre de combustion (Consulter la vue éclatée au dos de ce manuel – Illustration 6). Vous pouvez le faire ne soulevant la plaque et en la retirant. Il faut alors nettoyer soigneusement l'aire derrière la plaque et remettre celle-ci dans sa position originale.
ENTRETIEN : ATTENTION : DÉBRANCHER L'APPAREIL AVANT TOUT TRAVAIL D'ENTRETIEN! CONSULTER LA VUE ÉCLATÉE (ILLUSTRATION 6) POUR LA RÉFÉRENCE AUX PIÈCES Commandes de pièces : (800) 516-3636 www.heatredefined.com Questions: (800) 245-6489 REMARQUE: Les procédures de maintenance décrites dans ce manuel (y compris le nettoyage et l'inspection et le remplacement des pièces et des joints) sont disponibles sur youtube.com/heatredefined.
Commutateur d'aspiration Cet appareil dispose de commutateur d'arrêt d'aspiration (Pièce # CU-VS), qui aide à commander les nombreuses fonctions de l'appareil. S'il y a une erreur d'opération dans l'appareil, un commutateur arrêtera la vis sans fin supérieure (alimentation) ou arrêtera l'appareil); dans le cas de l'arrêt de l'appareil, un code E-1 (code d’erreur) apparaîtra dans les fenêtres du degré de chaleur et de la vitesse du ventilateur du tableau de commande.
Interrupteur de sécurité du couvercle de la trémie Cet appareil est également doté d’un interrupteur de sécurité du couvercle de la trémie (pièce no AC-HLSB) qui est directement raccordé au moteur de la vis à granules supérieure. Dans l’éventualité où le couvercle de la trémie est laissé ouvert pendant que le poêle est en marche, l’interrupteur du couvercle de la trémie empêchera la vis à granules supérieure de tourner.
Tableau de commande Le panneau de commande (Pièce # PU-CB19) est un panneau à lecture numérique Ce tableau offre de nombreux réglages pour faire fonctionner l'appareil. Cette pièce peut être retirée de l'appareil en desserrant les deux vis extérieures et en la tirant vers l'intérieur du poêle. Le panneau d'accès arrière doit être enlevé avant de retirer le tableau de commande. Ce tableau de commande dispose d'un fusible de 6 A à « déclenchement rapide » (Pièce # PU-CBF6).
Illustration 4 PU-CB19 Schéma du tableau de commande (câblage) SOUFFLERIE DE COMBUSTION ÉTIREUSE INFERIEURE COMMUTATEUR DE SECURITÉ DE TRÉMIE CÀBLE BLANC CAPTEUR FUSIBLE 6 THERMIQUE AMP CÀBLE NOIR IGNITEUR CAPTEUR SOUS VIDE COMMUTATEUR SOUS VIDE ÉTIREUSE SUPÉRIEURE Le tuyau de vide à haute température se connecte à l'arrière du foyer FLEXIBLE SOUS VIDE HAUTE TEMP SOUFFLERIE D'AIR DE SALLE TERRE VERTE LIGNE 120 VOLTS CAPTEUR THERMIQUE THERMOSTAT MURAL (J 18) ARRIÈRE DE CHAMBRE DE COMBUSTION ATT
Ajustement des loquets de couvercle de trémie Les joints autour du couvercle de la trémie pour granules sont importants pour la sécurité d'un fonctionnement efficace de l'appareil. Les loquets posés sur ces appareils sont conçus pour tirer le couvercle de la trémie serré contre ce joint. Au cours de l'utilisation comme ces joints s'usent et se compressent, il faut tester la tension des loquets périodiquement et ajuster au besoin.
ACCESSOIRES Vous pouvez ajouter les accessoires suivants à votre appareil en tout temps; cependant, vous devez le laisser refroidir avant de le faire. Thermostat Vous pouvez installer un thermostat mural externe sur nos appareils à granules de bois, pour autant qu'il fonctionne avec les systèmes à basse tension en millivolt. Après avoir débranché l'appareil, repérer le fil de connexion (J-18) en bas du tableau de commande. Il faut desserrer les deux vis et retirer le fil de connexion du tableau.
PIÈCES DE RECHANGE, ACCESSOIRES ET OPTIONS AC-GGK AC-DGKC AC-G9 AC-SHN AC-MBSP PU-047040 PU-BP02 PU-BP98WP PU-076002B AC-CT Kit de joint d'étanchéité de verre (joint uniquement) Kit de joint d'étanchéité de porte (#2 sur le schéma) Verre 22,8 cm x 22,8 cm (9 po x 9 po) avec joint d'étanchéité (#3 sur le schéma) Poignée de porte à ressort, en nickel Peinture noire haute température Ensemble moteur-vis sans fin 1 T/M (#18 sur le schéma) Ensemble de la chambre de combustion Plaque d'usure (s'adapte à l'intér
Poêle à granules de bois – Vue éclatée Illustration 6 Dimensions de votre appareil à granules : L 61 cm x H 72,4 cm x P 71,1 cm (24 po x 28,5 po x 28 po) 129,27 kg (285 lb) (Hauteur de plancher au centre de l'évacuation, environ 34,3 cm (13 ½ po).
GUIDE DE DÉPANNAGE MISE EN GARDE : POUR ÉVITER UN CHOC ÉLECTRIQUE TOUJOURS DÉCONNECTER L'APPAREIL DE LA SOURCE DE COURANT AVANT DE COMMENCER UNE RÉPARATION. SI CE GUIDE NE VOUS PERMET PAS DE CORRIGER LE PROBLÈME, APPELER VOTRE VENDEUR LOCAL OU NOTRE SUPPORT TECHNIQUE AU 1-800-245-6489. Problème 1. La vis sans fin ne tourne pas Cause Solution Vis de blocage desserrer Engrenage de moteur défectueux Matière étrangère dans la vis Capteur d'aspiration (Vis sans fin supérieure) 5.
Vous pouvez inscrire la date de fabrication et le numéro de série de votre appareil dans les espaces prévus à cet effet sur cette étiquette, pour référence ultérieure. Cette étiquette comprend également des renseignements de sécurité, tels que la norme d’essai UL/ULC et autres, à l’intention de vos représentants locaux ou de toute autre personne qui peut en avoir besoin.
Avoir l'information en main lorsque vous téléphonez à l'usine ou à votre vendeur au sujet de ce produit.
AVIS IMPORTANT : UN DOSSIER DOIT CONTENIR CETTE INFORMATION D'ENREGISTREMENT POUR QUE CETTE GARANTIE SOIT VALIDE. VEUILLEZ POSTER CETTE INFORMATION DANS LES TRENTE (30) JOURS À DATER DE L'ACHAT. Poster à : England’s Stove Works, Inc. Technical Support Department P.O. Box 206 Monroe, VA 24574 Ou télécopier à : (434) 929-4810 – 24 heures par jour Consulter www.heatredefined.com si vous préférez vous enregistrer en ligne.
ENREGISTREMENT DE GARANTIE pour England’s Stove Works Acheté par (Nom) ______________________________________________ Adresse _________________________________________________________ Ville ________________________ Province__________ Zip _________________ Téléphone _______________________________________________________ Adresse courriel ___________________________________________________ INFORMATION SUR LE VENDEUR Acheté de (Vendeur) ___________________________________________ Adresse ______________________
IMPORTANT! Lisez et suivez TOUTES les instructions pour l’installation et l’entretien, notamment celles portant sur le nettoyage de l’appareil à effectuer selon les directives et celles portant sur le remplacement des joints (annuellement) et des pièces (au besoin). England’s Stove Works n’est pas responsable des dommages ni des blessures, quels qu’ils soient, subis en raison de négligence ou à cause d’une installation ou utilisation dangereuse de ce produit.
POÊLE À GRANULES – Respecte les limites d’émission de REMARQUE : combustible de 2015 établies par l’Environmental Protection Agency des États‐Unis pour les poêles à bois vendus après le 15 mai 2015. RENSEIGNEMENTS SUR L’EPA Les ajouts suivants à votre guide d’utilisation vous permettront de réduire au minimum les émissions produites par votre poêle à bois. Des conseils de sécurité importants vous sont également présentés.
Renseignements supplémentaires sur la ventilation Ne mélangez pas et n’associez pas de pièces provenant de différents fabricants lorsque vous installez le système de ventilation (par exemple, n’utilisez PAS le tuyau d’un fabricant avec la gaine pour tuyau d’un autre fabricant). Il est nécessaire que le tuyau soit disposé verticalement sur au moins 91,44 cm pour créer un tirage naturel dans le système.
RACCORDEMENT À L’AIR EXTÉRIEUR L’air de combustion utilisé par ce poêle doit provenir de l’extérieur. Le tuyau de raccordement à l’air extérieur dépasse de la partie inférieure centrale à l’arrière du poêle. Utilisez l’ensemble de raccordement fourni avec le poêle pour raccorder celui‐ci à l’air extérieur. Les instructions ainsi que toutes les pièces nécessaires au raccordement de votre poêle à granules à l’air extérieur sont incluses dans l’ensemble de raccordement à l’air extérieur.
Remarques à propos de l’utilisation quotidienne Seuls des granules de bois de qualité, d’un diamètre de 6,4 mm (0,25 po), doivent être utilisés dans le poêle. L’utilisation de granules de moindre qualité contenant une grande quantité de cendres OU de granules dont le taux d’humidité est important peut provoquer un engorgement plus rapide du pot de combustion par les cendres et peut nécessiter un entretien périodique beaucoup plus fréquent.
Commande d’air : Votre poêle à granules est doté d’un panneau de commande qui règle automatiquement le rapport air/combustible pour garantir un rendement optimal. Consultez votre guide d’utilisation pour obtenir des renseignements sur l’utilisation du panneau de commande et sur la manière de garantir une combustion optimale.
‐ RETRAIT DES CENDRES – Suivez les instructions du guide d’utilisation concernant le retrait et l’élimination des cendres. Assurez‐vous également de suivre TOUTES les exigences d’entretien indiquées. ‐ REMPLACEMENT des pièces essentielles à un taux d’émission faible – Suivez les instructions du guide d’utilisation concernant le remplacement des joints et des autres pièces essentielles à un taux d’émission faible.