7.7 AFCSettings
Parameters: staloID staloMinTuneRFFreq staloMinTuneUnit staloMaxTuneRFFreq staloMaxTuneUnit 
afcCoarseFreqStep afcFineFreqStep afcTuneBandwidth afcBurstIFFreq afcFreqThresh 
afcBurstPowerThresh afcLoopSettingTime afcStaloNominalFreq flags
staloID  - uint
staloMinTuneRFFreq  - float in MHz
staloMinTuneUnit  - float in V
staloMaxTuneRFFreq  - float in MHz
staloMaxTuneUnit  - float in V
afcCoarseFreqStep  - float in kHz
afcFineFreqStep  - float in kHz
afcTuneBandwidth  - float in MHz
afcBurstIFFreq  - float in MHz
afcFreqThresh  - float in kHz
afcBurstPowerThresh  - floa in dBt
afcLoopSettingTime  - float in ms
afcStaloNominalFreq  - float in MHz
flags  - uint, bits with following masks control the settings
   0x0001 - Negative AFC Tuning Slope
0x0002  - Invert IQ
0x0100  - AFC
0x0200  - MFC
0x0400 - MFC Hold
0x0800  - AFC Search
0x1000  - Set Mode Only
7.8 DualPolMode
If true, dual polarization mode is used, otherwise single polarization mode. Ray format depends on the 
parameter.
Type:  boolean
Default:  false
7.9 Dual polarization specific parameter
When used in dual polarization mode the ENIGMA signal processor will use the following cammands in 