User manual
Code: ENIGMA III User Manual
Edition: 1 Revision: 4
Date: 19/12/2008
Page: 71/97
7.9.1 ZdrOffset
The bias in the horizontal/vertical receiver path needs to be calibrated in order to get a ZDR reading of 
zero for the first range gate. The corresponding parameter is ZDROffset.
Type: float
Default: 0
Unit: dB
7.9.2 LdrOffset
The bias in the horizontal/vertical receiver path needs to be calibrated in order to get a LDR reading of 
zero for the first range gate. The corresponding parameter is LDROffset.
Type: float
Default: 0
Unit: dB
7.9.3 PhidpOffset
The constant phase difference between the horizontal/vertical receiver channel needs to be calibrated in 
order   to   get   a   PhiDP  reading   of   zero   for   the   first   range   gate.   The   corresponding   parameter  is 
PhidpOffset.
Type: float
Default: 0
Unit: degree
7.9.4 RHOHVThreshold
In dual polarization mode the RhoHV (cross correlation between horizontal and vertical channel) 
coefficient can be used as threshold parameter. The threshold flags need to be set accordingly.
Type: float
Default: 0
7.10 DataFormat
Output data format type. Ray format depends on the parameter. In single pol mode:
● 0 - Angle Data
● 1 - Moments 8 bit
GAMIC Proprietary










