ELECTRICAL REQUIREMENTS
AND INSTALLATION
The following information is provided for hooking up electrical supply to
yournewspa.Aqualied,licensed,electricianmustperformthiswork.
Failure to follow these instructions will terminate all warranty coverage
and can cause serious injury or death.
Your Allegro spa is preset at the factory to run on 240V with a 48 amp
input. This feature gives you the most performance out of your spa.
This will require a 240V, 60-amp GFCI. If a 60-amp service is not avail-
able.
The Allegro spas may also be setup to run off of 120VAC. See page
14 for conversion information.
ELECTRICAL WIRING FOR 240VAC SETUP
WARNING: Your spa must be wired by a certied electrician and
according to these instructions. Failure to do so will terminate all
warranties and all listings from the independant listing facility.
1) The Platinum Class Spa requires a 240 VAC dedicated
system. The spa must be hardwired to the power supply, with no
plug-in connections, extension cords, or sharing of service.
2) The spa requires that you run 6 or 8 AWG copper wire, depending
on the GFCI size. Do Not Use Aluminum Wire.
3) The power supply must have a suitable Ground Fault Circuit
Interrupter (GFCI), according to Section 422-20 of the National
Electrical Code, ANSI/NFPA 70-7987. This could be used as the
shut-off switch, which must be installed in plain view of the spa. This
electrical service must be readily accessible to the spa occupants,
but must not be within 5 feet of the spa.
4)Useonlynon-metallicconduitandttingswheninstallingpowerto
the spa.
5) After your spa has been positioned, route lines through the knockout
on the left or right front corner of the spa.
10