Owner`s manual
SPA START-UP cont...
TESTING THE GFCI BREAKER cont...
NOTE: When power is turned on, your spa is automatically
programmed to start circulating water for 5 minutes. Adjust your
temperature by pressing the “Warm” button on your touchpad
until the desired temperature is displayed. This setting will allow
your spa to heat to the set temperature.
CAUTION: If water is not noticeably coming from your spa jets
during the automatic purge, turn on the high speed pump. If water
is still not coming from the jets, the pump needs to be manually
primed, following the steps below.
PRIMING THE PUMP
1) Turn off power at electrical service panel.
2) Locate and loosen the pump by turning it counterclockwise one half
of one turn.
3)Allowairtoescapefromthetting.Whenasteadystreamofwater
owsfromthepumpplug,closeitbyturningitclockwiseuntiltight.
4) Turn on power at electrical service panel.
5)Checkoncemoretomakesurethatwaterisowingfromthejets
during auto purge. If so, continue. If no water is coming from your
spa jets, please call your Artesian dealer for further assistance.
WATER PREPARATION
NOTE: Before putting your new spa into operation, understand
that preparing your new water is an important part of
maintenance. Failure to properly prepare your water can result
in substantially decreasing the life of the components and may
void your warranty in severe cases. Your Artesian dealer should
have a start-up and maintenance kit available for you when you
receive your spa.
18