Owner`s manual

23
Diagnostic Messages
Temperature unknown.
After the pump has been running for 2 minutes, the
temperature will be displayed
“Overheat” - The spa has shut down. One of the sensors has
detected 118°F/48°C at the heater.
DO NOT ENTER THE WATER. Remove the spa cover and
allow water to cool. Once the heater has cooled, reset
by pushing any button. If spa does not reset, shut off
the power to the spa and call your dealer or service
organization.
“Overheat” - The spa has shut down. One of the sensors has
detected that the spa water is 110°F/43°C.
DO NOT ENTER THE WATER. Remove the spa cover
and allow water to cool. At 107°F/42°C, the spa should
automatically reset. If spa does not reset, shut off
the power to the spa and call your dealer or service
organization
“Ice - Potential freeze condition
No action required. The pump and blower will
automatically activate regardless of spa status.
Spa is shut down. The sensor that is plugged into the
Sensor A jack is not working.
If the problem persists, contact your dealer or service
organization. (May appear temporarily in an overheat
situation and disappear when the heater cools.)