Owner`s manual
5
Dream Series Control
YOUR • QCA • SPA • EQUIPMENT
Initial Start Up
When your spa is first powered up, it will go into Priming
Mode, indicated by “Pr”. Priming mode will last for 5
minutes and then the spa will being to heat the spa and
maintain water temperature in the Standard Mode. During
this cycle do not press any buttons as it will cause the
priming mode to start over.
Temperature Control
The start-up temperature is set at 100ºF. The last
measured temperature is constantly displayed on the LCD.
Note that the last measured spa temperature displayed is
current only when the pump has been running for at least
two minutes.
Press the “Temp” button to display the temperature
previously set. This set temperature is flashed on the
display. Pressing the “Temp” button a second time, while
it is still flashing, will cause the set temperature to
increase or decrease depending on what direction was last
chosen. Each press to follow will change the set
temperature in the same directions. If the opposite
direction is desired, release the pad and let the display
revert to the actual water temperature. Press the button to
display the set temperature, and again to make the
temperature change in the desired direction.
Jets
Touch the “Jets” button once to activate the low speed of
the pump and again for the high speed. Press the “Jets”
button again to turn off the pump. If left running, the
pump’s low speed will automatically turn off after four
hours, and the pump’s high speed will automatically turn
off after 15 minutes. The low speed of the pump runs
when the blower is on. It may also activate for at least
two minutes every 30 minutes to detect the spa
temperature and then to heat to the set temperature if
needed, depending upon mode. When the low speed turns
on automatically, it cannot be deactivated from the panel;
however, the high speed may be started.
Light
Press the “Light” button to turn the light on and off. If left
on, the light automatically turns off after four hours.
Preset Filter Cycles
The first filter cycle begins six minutes after the spa is
energized. The second filter cycle begins 12 hours later.
Filter duration is programmable at the Master Control Pad
for 2, 4, 6, 8 hours or for continuous filtration, (indicated
by “FC”). The default filter time is two hours. To
program, press “Temp”, then “Jets.” Press “Temp” to
adjust. Press “Jets” to exit programming.
Freeze Protection
If the temperature sensors detect a drop below 40ºF
within the heater, then the pump (as well as the heater,
if necessary) will automatically activate to provide
freeze protection. The equipment stays on until the
sensors detect that the spa temperature has risen to
within 15ºF of the set temperature. The blower will
purge for 30 seconds at the end of the freeze
condition.
WARNING
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance
with the manufacturer's instruction, may cause interference to radio and television reception. It has been type tested and
found to comply with the limits for a class B computing device in accordance with the specification in subpart J of part 15
of the FCC rules, which are designed to provide reasonable protection against such interference in a residential installation.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
interference, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the
interference by one or more of the following measurers: Reorient the receiving antenna. Relocate the receiver with respect
to the spa. Move the receiver away from the spa. Plug the receiver into a different outlet so that the receiver and spa are on
different circuits. If necessary, the user may find the following booklet prepared by the Federal Communications
Commission helpful: "How to identify and resolve radio-TV interference problems." This booklet is available from the U.S.
Government Printing Office, Washington, DC 20402, Stock No. 004-00000345-4.