PTM 210 / PTM 215 / PTM 21U User Manual
January 2012
Page 13/19
PTM 210 / PTM 215 / PTM 210 U
2.2 Contact Nipples Designation
With 4 contact nipples, the PTM 21x offers 2 channels with 4 action states each (up-
per/lower nipple is pressed/released when activating the energy bow). The nipples’ desig-
nation is as follows:
Contact nipple designation
2.3 Operating modes
There are 2 operating modes:
Normal mode: PTM 210, PTM 210U and PTM 215
Secure mode: PTM 215
After production, PTM 215 is set to “normal mode”.
Radio signals of the PTM 21x are event-controlled (energy bow is pressed/released) with
contact nipple code (channel/state) and unique device identification (fixed 32-bit ID).
2.3.1 Normal mode (PTM 210, PTM 210U, PTM 215)
In normal mode, PTM 21x sends telegrams according to EEP F6-02-xx and F6-04-xx as
specified in EnOcean Equipment Profiles V2.1. Details see:
http://www.enocean-alliance.org/fileadmin/redaktion/enocean_alliance/pdf/EnOcean_Equipment_Profiles_EEP2.1.pdf
Due to the mechanical hysteresis of the energy bow, in most rocker switch device
implementations, pressing the rocker sends an N-message and releasing the rock-
er sends a U-message!
O
I
BA
CHANNEL
STATE
O
I
BA
CHANNEL
STATE