User's Manual

USER MANUAL PREVIEW
PTM 535BZ BLUETOOTH AND ZIGBEE GREEN POWER PUSHBUTTON TRANSMITTER
© 2022 EnOcean | www.enocean.com F-710-017, V1.0 PTM 535BZ User Manual | v1.2 | July 2021 | Page 29/121
4.2 Radio transmission sequence
PTM 535BZ transmits ZGP data telegrams as a set of redundant transmissions where the
same data telegram is transmitted 3 times. The timing interval between the start of two
consecutive redundant data telegrams is approximately 2.5 ms and varies by some random
timing offset.
Figure 20 below shows the ZGP radio transmission sequence used by PTM 535BZ for data
telegrams.
Figure 20 – ZGP radio transmission sequence for data telegrams
PTM 535BZ transmits ZGP commissioning telegrams (which are much longer than ZGP data
telegrams) as a set of redundant transmissions where the same data telegram is transmitted
2 times. The timing interval between the start of the two consecutive redundant commission-
ing telegrams is approximately 2.5 ms and varies by some random timing offset.
Figure 21 below shows the ZGP radio transmission sequence used by PTM 535BZ for com-
missioning telegrams.
Figure 21 – ZGP radio transmission sequence for commissioning telegrams