User's Manual

USER MANUAL PREVIEW
PTM 535BZ BLUETOOTH AND ZIGBEE GREEN POWER PUSHBUTTON TRANSMITTER
© 2022 EnOcean | www.enocean.com F-710-017, V1.0 PTM 535BZ User Manual | v1.2 | July 2021 | Page 33/121
ZGP command (2 byte or 1 byte)
The ZGP command identifies the switch action. Format and encoding used by the ZGP
command depend on the selected device ID.
Security Signature (4 byte)
The Security Signature is used to authenticate PTM 535BZ ZGP radio telegrams as
described in chapter 4.4.4
4.4.1.1 Device ID
The application data format within the data telegram is determined by the ZGP Device ID
which identifies the device type as defined by the ZGP specification [3].
Table 6 below lists the ZGP Device ID that are supported by PTM 535BZ.
Device ID Description Payload size
0x00 Simple Generic 1-state Switch 1 byte
0x01 Simple Generic 2-state Switch 1 byte
0x02 ON / OFF Switch 1 byte
0x03 Level Control Switch 1 byte
0x05 Advanced Generic 1-state Switch 1 byte
0x06 Advanced Generic 2-state Switch 1 byte
0x07 (Default) Generic 8-contact Switch 2 byte
0x10 GP Color Dimmer Switch 1 byte
Table 6 – Supported ZGP Device ID
The default Device ID used by PTM 535BZ is 0x07 (Generic 8-contact Switch) as described
in Chapter 4.4.1.2.
It is possible to select another supported Device ID via the NFC interface. In that case, it is
required to define the set of commands to be used for the different input events as described
in Chapter 4.4.1.3.