User's Manual

USER MANUAL
TCM 300 / TCM 300C / TCM 300U
TCM 320 / TCM 320C / TCM 320U
3.10 Smart Acknowledge
TCM 3x0 modules provide a post master function with 15 mail boxes for systems using
EnOcean smart acknowledge technology. This functionality is switched on in all operating
modes.
For detailed information on smart acknowledge please refer to the Smart Acknowledge sys-
tem specification.
When teaching-in a device using Smart Acknowledge please take care to switch off
all TCM 3x0 devices which are not continuously powered. Otherwise these TCM
3x0 modules could be declared postmaster. As soon as the power supply is
switched off a postmaster would be missing and Smart Acknowledge would not
work any longer!
3.11 Transmit timing
The setup of the transmission timing allows avoiding possible collisions with data packages
of other EnOcean transmitters as well as disturbances from the environment. With each
transmission cycle, 3 identical subtelegrams are transmitted within 40 ms. The transmis-
sion of a subtelegram lasts approximately 1.2 ms. The delay between the three transmis-
sion bursts is affected at random.