4.7 Soldering information
4.7.1 TCM 300x
TCM 300x has to be soldered according to IPC/JEDEC J-STD-020C standard.
TCM 300x shall be handled according to Moisture Sensitivity Level MSL4 which means a
floor time of 72 h. TCM 300 may be soldered only once, since one time is already consumed
at production of the module itself.
Once the dry pack bag is opened, the desired quantity of units should be removed and the
bag resealed within two hours. If the bag is left open longer than 30 minutes the desiccant
should be replaced with dry desiccant. If devices have exceeded the specified floor life time
of 72 h, they may be baked according IPC/JEDEC J-STD-033B at max. 90 °C for less than
60 h.
Devices packaged in moisture-proof packaging should be stored in ambient conditions not
exceeding temperatures of 40 °C or humidity levels of 90% r.H.
TCM 300x modules have to be soldered within 6 months after delivery!