User's Manual

USER MANUAL
TCM 300 / TCM 300C / TCM 300U
TCM 320 / TCM 320C / TCM 320U
A.3 Command telegrams and messages
Before sending the next command via serial interface please always wait for the
response to the previous command from the module. The reaction time is below
5ms. Be aware that an already received radio telegram might (concurrently to the
command) be sent through the serial port before the command gets processed.
A.3.1 ID Range commands
Every TCM 300 supports a unique 32 bit ID and in addition a range of 128 IDs starting at
an BaseID address. At production, every TCM 300 is programmed with a unique ID and a
BaseID address. The BaseID number can be read via the serial interface. In order to allow a
replacement of one unit with another unit (without having to go through the learning pro-
cedure with every receiver), the ID range can be changed via the serial interface.
The allowed ID range is from 0xFF80_0000 to 0xFFFF_FFFE.
32 0
BaseID
0xFFFF_FFFF cannot be used. This address is reserved as broadcast ID.
In order to prevent misuse, this feature can only be used 10 times!
Please note: The unique ID cannot be changed.
Command (TCT)
Response (RCT)
SET_BASEID
OK, ERR, ERR_IDRANGE
RD_BASEID
INF_BASEID
A.3.2 Receiver sensitivity commands
The receiver sensitivity can be changed by the following commands. In LOW sensitivity
mode, only transmitters in the vicinity of the module are received.
Command (TCT)
Response (RCT)
SET_RX_SENSITIVITY
OK
RD_RX_SENSITIVITY
INF_RX_SENSITIVITY
A.3.3 Reset command
Command (TCT)
Response (RCT)
RESET
A.3.4 SW Version
Command (TCT)
Response (RCT)
RD_SW_VER
INF_SW_VER
25 most significant bits
0
0
0
0
0
0
0