SDS

3
SECTION 8 EXPOSURE CONTROL / PERSONAL PROTECTION
Exposure Limits
ACGIH TLV OSHA PEL Other (specify)
Specific Engineering Controls (such as ventilation, enclosed process)
Adequate ventilation and appropriate local exhaust where needed to keep dust level below PEL.
Personal Protective Equipment
Gloves Respirator Eye Footwear Clothing Other
If checked, please specify type
Eye: Goggles to protect from dust.
Skin: No special equipment is required.
Respiratory: Respirators fitted with filters certified to standard 42CFR84 under series N95 should be worn when dust is present. If the dust
concentration is less than ten (10) time the Permissible Exposure Limit (PEL) use a quarter or half mask respirator. If dust
concentration is greater than ten (10) times and less than fifty (50) times the PEL, a full-face piece respirator fitted with replaceable
N95 filters is recommended. If dust concentration is greater than fifty (50) and less than
two-hundred (200) times the PEL use a power air-purify (positive pressure) respirator with replaceable N95 filter. If dust concentration
is greater than two-hundred (200) times the PEL use a type C, supplied air respirator (continuous flow, positive pressure), with
full face piece, hood or helmet.
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES
Physical State
Odor and Appearance
Odor Threshold (ppm)
Solid
White Granules or Powder. No distinct
odor.
N/A
Specific Gravity
Vapor Density (air = 1)
Vapor Pressure (mmHg)
2.35
N/A
N/A
Evaporation Rate
Boiling Point (° C)
Freezing Point (° C)
N/A
N/A
N/A
pH
Coefficient of Water/Oil Distribution
[Solubility in Water]
6-10
N/A
Slightly Soluble