Enphase IQ8 Install and Operation Manual
IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation
25 © 2022 Enphase Energy Inc. All rights reserved. Aug 2022
• Press the Device Scan button on the IQ Gateway. The IQ Gateway begins a 15-minute scan
to identify all of the microinverters deployed at the site. The Microinverter Communications
LED flashes green during the scan.
K. Log in to Enphase Installer platform to use Enphase installer platform’s Array Builder to add the newly detected
microinverter to the virtual array.
L. Ship the old microinverter to Enphase using the supplied return-shipping label.
Replacement Parts and Cabling
Ordering Replacement Parts
Replacement adaptors for Microinverters with MC-4 DC connectors include:
• Q-DCC-2: Cable Assembly, DC adaptor to MC-4
These parts are available from your Enphase distributor.
Enphase IQ Cable Planning and Ordering
The Enphase IQ Cable is a continuous length of 12 AWG, double insulated, outdoor-rated cable with integrated
connectors for microinverters. These connectors are preinstalled along the IQ Cable at intervals to accommodate varying
PV module widths. The microinverters plug directly into the cable connectors.
The cabling is compatible with a variety of PV racking systems. For a list of approved PV racking systems, refer to the
PV Racking Compatibility document on the Enphase website at enphase.com/support.
Connector Spacing Options
IQ Cable is available in three connector spacing options. The gap between connectors on the cable can be 1.3 meters,
2.0 meters, or 2.3 meters. The 1.3 meter spacing is best suited for connecting PV modules installed in portrait
orientation, while the 2.0 meter and 2.3 meter spacing allows you to install 60-cell and 72-cell PV modules in landscape
orientation, respectively
Cabling Options
Ordering options include:
Cable Model
Connector spacing
PV module orientation
Connector count per box
Q-12-10-240
1.3m (50”)
Portrait
240
Q-12-17-240
2.0m (78”)
Landscape (60-cell)
240
Q-12-20-200
2.3m(90”)
Landscape (72-cell)
200
Microinverter Communications LED
Device Scan button