Enphase IQ8 Install and Operation Manual

IQ8 / IQ8+ / IQ8M / IQ8A / IQ8H Micro Installation and Operation
31 © 2022 Enphase Energy Inc. All rights reserved. Aug 2022
Enphase IQ8PLUS-72-2-US Microinverter Parameters
Topic
Unit
Min
Typical
Max
Miscellaneous Parameters
Maximum
3
microinverters per 20A (max) AC branch circuit
240 VAC (single phase)
13
CEC weighted efficiency 240 VAC (single phase)
%
97.0%
Total harmonic distortion
%
<5
Ambient temperature range
°C
-40
+60
Night-time power consumption
mW
60
Storage temperature range
°C
-40
+85
Features and Specifications
Compatibility
60-cell/120 half-cell, 66-cell and 72-cell/144 half-cell
Dimensions not including mounting bracket
212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”)
Connector Type
Enphase IQ™ Connector
Weight
1.08 kg (2.38 lbs)
Environmental Category/ UV exposure rating
NEMA Type 6 / outdoor
Torque specifications for fasteners
(Do not over torque)
6 mm (1/4”) mounting hardware: 5 N m (45 to 50
in-lbs.)
8 mm (5/16”) mounting hardware: 9 N m (80 to 85
in-lbs.)
When using UL 2703 mounting hardware, use the
manufacturer’s recommended torque value
Cooling
Natural convection - No fans
Relative Humidity range
4% to 100% (condensing)
Approved for wet locations
Yes
Pollution degree
PD3
Standard Warranty Term
http://enphase.com/warranty
Enphase IQ8Plus-72-2-US Microinverter Parameters
Compliance
CA Rule 21 (UL 1741-SB), UL 62109-1,
UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003
Class B, CAN/CSA-C22.2 NO. 107.1-01
This product is UL Listed as PV Rapid Shut Down
Equipment and conforms with NEC 2014, NEC 2017,
and NEC 2020 section 690.12 and C22.1-2018 Rule
64-218 Rapid Shutdown of PV Systems, for AC and
DC conductors, when installed according to
manufacturer’s instructions.
Grounding
The DC circuit meets the requirements for ungrounded
PV arrays in NEC. Ground fault protection (GFP) is
integrated into the class II double insulated
microinverter
Monitoring
Enphase Installer Platform and Enphase App
monitoring options. Both options require an Enphase
IQ Gateway
Communication
Power line communication (PLC)
(1) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (2) Nominal voltage range can
be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per
branch in your area.