IQ Load Controller Additional Info

Load and Solar Circuit Control using IQ System Controller Auxiliary Contacts
26 © 2021 Enphase Energy Inc. All rights reserved. December 16, 2021
Example Wiring: Heavy 240V Load Shedding for 1X Circuit
Figure 25: Example Wiring: Heavy 240V Load Shedding for 1X Circuit
Using an external contactor with a 120Vac coil
24 Vac coil based definite purpose contactors for large loads typically have holding currents that exceed
IQ System Controller auxiliary contact rating of 1 A. In such cases an external contactor with a 120 Vac
coil can be used with the bill of materials and wiring specified in this section. A 12 V DC power source is
used to drive an interposing power relay and the auxiliary contacts in IQ System Controller controls the
current to the coil of the power relay. The output of the power relay is used to control the 120 Vac coil of
the external contactor.