IQ Load Controller Additional Info

Load and Solar Circuit Control using IQ System Controller Auxiliary Contacts
9 © 2021 Enphase Energy Inc. All rights reserved. December 16, 2021
Scheduled Mode: When off-grid, shed loads at a certain time of the day
In this mode, installer is provided the ability to set a certain time interval of the day when the connected
loads would be powered when system is off-grid. At other times, if system is off-grid, these loads remain
powered off.
Note: If homeowner site does not have a battery installed, the allow time window to schedule load control
is 9am to 4pm. For a site with battery, any time in 24 hours can be scheduled.
Mode
MID
Time of day
Load circuit state
on-grid
MID Closed
Any
Connected
off-grid
MID Open
Outside scheduled
time
Disconnected
off-grid
MID Open
Within scheduled
time
Connected
Table 2: Scheduled mode
Figure 7 Scheduled mode: Automatically control load when off-grid at certain times of the day using
Enphase Installer App
1. Select radio button ‘Scheduled’
2. Set Start Time and End time for the duration during which loads are to remain powered when off-
grid and click ‘Apply’